60W Single Output Switching Power Supply
AT-60 ꢀerieꢀ
ꢏꢃꢆꢍꢌꢄꢃꢅꢈꢔ
�ꢀꢁꢂꢃꢄꢅꢆꢇꢈꢉꢊꢈꢁꢀꢋꢌꢍꢈꢎꢈꢏꢌꢇꢇꢈꢄꢆꢀꢐꢃ
ꢑꢄꢒꢍꢃꢓꢍꢁꢒꢀꢅꢔꢕꢖꢒꢄꢍꢈꢓꢁꢄꢓꢌꢁꢍꢎꢗꢂꢃꢄꢈꢇꢒꢆꢘꢎꢗꢂꢃꢄꢈꢂꢒꢇꢍꢆꢐꢃ
ꢊꢒꢒꢇꢁꢀꢐꢈꢙꢚꢈꢛꢄꢃꢃꢈꢆꢁꢄꢈꢓꢒꢀꢂꢃꢓꢍꢁꢒꢀ
ꢜꢝꢞꢈꢁꢀꢘꢁꢓꢆꢍꢒꢄꢈꢛꢒꢄꢈꢋꢒꢟꢃꢄ ꢒꢀ
ꢏꢁꢠꢃꢘꢈꢅꢟꢁꢍꢓꢖꢁꢀꢐꢈꢛꢄꢃꢡꢌꢃꢀꢓꢚꢈꢆꢍꢈꢢꢣꢤꢥꢦ
ꢧꢈꢚꢃꢆꢄꢅꢈꢟꢆꢄꢄꢆꢀꢍꢚ
SPECIFICATION
MODEL
T-60A
AT-60A
T-60B
AT-60B
T-60C
AT-60C
OUTPUT�NUMBER
DC�VOLTAGE
CH1
CH2
CH3
-5V
CH1
CH2
CH3
CH1
CH2
15V
CH3
5V
12V
5V
12V
-12V
0.5A
0�~�1A
5V
-15V
0.5A
0�~�1A
RATED�CURRENT
CURRENT�RANGE
RATED�POWER
5A
2.5A
0.5A
0�~�1A
5A
2.5A
5A
2A
0.5�~�7A
57.5W
0.2�~�3.5A
0.5�~�7A
61W
0.2�~�3.5A
0.5�~�7A
62.5W
100mVp-p
0.2�~�3A
RIPPLE�&�NOISE�(max.) Note.2 100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
OUTPUT
VOLTAGE ADJ.�RANGE
CH1�:�4.75�~�5.5V
CH1�:�4.75�~�5.5V
CH1�:�4.75�~�5.5V
VOLTAGE�TOLERANCE Note.3 2.0%
6.0%
1.0%
4.0%
6.0%
0.5%
1.0%
2.0%
0.5%
1.0%
6.0%
6.0%
0.5%
1.0%
2.0%
0.5%
1.0%
6.0%
6.0%
0.5%
1.0%
LINE�REGULATION
LOAD�REGULATION
SETUP,�RISE�TIME
HOLD�TIME (Typ.)
0.5%
1.0%
1.0%
4.0%
1.0%
4.0%
300ms,�50ms/230VAC
800ms,�50ms/115VAC�at�full�load
80ms/230VAC 10ms/115VAC�at�full�load
VOLTAGE�RANGE
85�~�264VAC����������120�~�370VDC
47�~�63Hz
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC�CURRENT (Typ.)
INRUSH�CURRENT (Typ.)
LEAKAGE�CURRENT
72%
72%
72%
INPUT
2A/115VAC����������1A/230VAC
COLD�START 20A/115VAC����������40A/230VAC
<3.5mA /�240VAC
105�~�150% rated�output�power
OVER�LOAD
Protection�type�:�Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
5V:�5.75�~�6.75V
PROTECTION
OVER�VOLTAGE
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
-10�~�+60 (Refer�to�output�load�derating�curve)
20�~�90%�RH non-condensing
WORKING�TEMP.
WORKING�HUMIDITY
-20�~�+85 ,�10�~�95%�RH
ENVIRONMENT STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
0.03%/ (0�~�50 )on�+5V�output
10~500Hz,�2G�10min./1cycle,�period�for 60min.�each�along�X, Y,�Z�axes
VIBRATION
SAFETY STANDARDS
WITHSTAND�VOLTAGE
UL1012,�UL60950, TUV�EN60950 Approved
I/P-O/P:3KVAC�����I/P-FG:1.5KVAC�����O/P-FG:0.5KVAC
ISOLATION�RESISTANCE
SAFETY &
I/P-O/P,�I/P-FG,�O/P-FG:100M�Ohms/500VDC
Compliance�to�EN55022�(CISPR22)�Class�B
Compliance�to EN61000-3-2,-3
EMI�CONDUCTION�&�RADIATION
HARMONIC�CURRENT
EMS�IMMUNITY
MTBF
EMC
(Note�4)
Compliance�to�EN61000-4-2,3,4,5,6,8,11;�ENV50204,�EN55024,�Light�industry�level,��criteria A
281.1K�hrs�min.������MIL-HDBK-217F�(25
159*97*38mm�(L*W*H)
)
OTHERS
NOTE
DIMENSION
0.55Kg;�24pcs/14.1Kg/0.75CUFT
PACKING
ꢨꢩꢈꢉꢇꢇꢈꢋꢆꢄꢆꢪꢃꢍꢃꢄꢅꢈꢫꢗꢬꢈꢅꢋꢃꢓꢁꢆꢇꢇꢚꢈꢪꢃꢀꢍꢁꢒꢀꢃꢘꢈꢆꢄꢃꢈꢪꢃꢆꢅꢌꢄꢃꢘꢈꢆꢍꢈꢧꢭꢣꢮꢉꢊꢈꢁꢀꢋꢌꢍꢯꢈꢄꢆꢍꢃꢘꢈꢇꢒꢆꢘꢈꢆꢀꢘꢈꢧꢢ ꢒꢛꢈꢆꢪꢙꢁꢃꢀꢍꢈꢍꢃꢪꢋꢃꢄꢆꢍꢌꢄꢃꢩ
ꢧꢩꢈꢰꢁꢋꢋꢇꢃꢈꢱꢈꢀꢒꢁꢅꢃꢈꢆꢄꢃꢈꢪꢃꢆꢅꢌꢄꢃꢘꢈꢆꢍꢈꢧꢣꢲꢥꢦꢈꢒꢛꢈꢙꢆꢀꢘꢟꢁꢘꢍꢖꢈꢙꢚꢈꢌꢅꢁꢀꢐꢈꢆꢈꢨꢧꢳꢈꢍꢟꢁꢅꢍꢃꢘꢈꢋꢆꢁꢄꢴꢟꢁꢄꢃꢈꢍꢃꢄꢪꢁꢀꢆꢍꢃꢘꢈꢟꢁꢍꢖꢈꢆꢈꢣꢩꢨꢌꢛꢈꢱꢈꢵꢶꢌꢛꢈꢋꢆꢄꢆꢇꢇꢃꢇꢈꢓꢆꢋꢆꢓꢁꢍꢒꢄꢩ
ꢭꢩꢈꢬꢒꢇꢃꢄꢆꢀꢓꢃꢈꢔꢈꢁꢀꢓꢇꢌꢘꢃꢅꢈꢅꢃꢍꢈꢌꢋꢈꢍꢒꢇꢃꢄꢆꢀꢓꢃꢯꢈꢇꢁꢀꢃꢈꢄꢃꢐꢌꢇꢆꢍꢁꢒꢀꢈꢆꢀꢘꢈꢇꢒꢆꢘꢈꢄꢃꢐꢌꢇꢆꢍꢁꢒꢀꢩ
ꢵꢩꢈꢬꢖꢃꢈꢋꢒꢟꢃꢄꢈꢅꢌꢋꢋꢇꢚꢈꢁꢅꢈꢓꢒꢀꢅꢁꢘꢃꢄꢃꢘꢈꢆꢈꢓꢒꢪꢋꢒꢀꢃꢀꢍꢈꢟꢖꢁꢓꢖꢈꢟꢁꢇꢇꢈꢙꢃꢈꢁꢀꢅꢍꢆꢇꢇꢃꢘꢈꢁꢀꢍꢒꢈꢆꢈꢛꢁꢀꢆꢇꢈꢃꢡꢌꢁꢋꢪꢃꢀꢍꢩꢈꢬꢖꢃꢈꢛꢁꢀꢆꢇꢈꢃꢡꢌꢁꢋꢪꢃꢀꢍꢈꢪꢌꢅꢍ ꢙꢃꢈꢄꢃꢴꢓꢒꢀꢛꢁꢄꢪꢃꢘꢈꢍꢖꢆꢍꢈꢁꢍꢈꢅꢍꢁꢇꢇꢈꢪꢃꢃꢍꢅ
ꢝꢲꢊꢈꢘꢁꢄꢃꢓꢍꢁꢂꢃꢅꢩ
300 Myleꢀ standiꢀh Blvd., Taunton, MA 02780
WWW.AsTRODYNE.COM
Ph: 1-800-823-8082
Fax: 508-823-8181