12
Composition of options
Note: Product names appearing herein are trademarks or registered trademarks of various companies.
Logic signal measurement
Input modules
Install by inserting into the main unit. Can be replaced by user.
Note: Input cables are not supplied. Please purchase the appropriate cable
for the intended application.
ANALOG UNIT 8936
VOLTAGE/TEMP UNIT 8937
FFT ANALOG UNIT 8938
STRAIN UNIT 8939
LOGIC PROBE 9320
4-channel type, for voltage/contact
signal ON/OFF detection
LOGIC PROBE 9321
4 isolated channels, ON/OFF detection
of AC/DC voltage
F/V UNIT 8940
4ch ANALOG UNIT 8946 (The 8946 can be used with the
8835-01, but cannot be used with the 8835.)
CHARGE UNIT 8947
Current measurement * The 3274, 3275, and 3276 cannot be used for the F/V UNIT 8940
F/V UNIT 8940
9279 Not CE certified
3273-50
Voltage measurement
9277
9278
CONVERSION CABLE 9319 (to connect 3273-50 and 8940)
CONVERSION CABLE 9318 (to connect 9277 - 9279 and 8940)
UNIVERSAL CLAMP ON CT 9277 CLAMP ON PROBE 3273-50
Observe waveforms from DC to distorted
AC. DC to 100kHz response, input 20A /
output 2V AC
DC to 50MHz wideband response,
mA-class current up to 30A rms
CONVERSION CABLE 9319
to connect 3273-50 and 8940
DIFFERENTIAL PROBE 9322
CONNECTION CORD
For up to 2kV DC or 1kV AC, AC adapter
UNIVERSAL CLAMP ON CT 9278
Observe waveforms from DC to distorted
AC. DC to 100kHz response, input 200A /
output 2V AC
9197
9418-15 required for operation.
For high voltage (up to 500V)
CONNECTION CORD 9217
Cord has insulated BNC connectors
at both ends, and connects to the
9555-10 and input moduls.
AC ADAPTER 9418-15
For powering Differential probe 9322,
100 to 240V AC, 12V/2.5 A
UNIVERSAL CLAMP ON CT 9279
Observe waveforms from DC to distorted
AC. DC to 20kHz response, input 500A /
output 2V AC
SENSOR UNIT 9555-10
POWER CORD
Model 9555-10 is required to power the Clamp-
On CTs, except for connecting Clamp-On CT
Model 9277/78/79 to Model 8940, and for
signal output, Model 9217 Connection Cord is
required to connect for input modules.
9324
CONVERSION CABLE 9318
CONNECTION CORD
Use to the 9322 from the logic terminal.
MEMORY HiCORDER 8835-01 (main unit)
to connect 9277/9278/9279 and 8940
* Note that usage restrictions apply.
9198
* The MEMORY HiCORDER 8835-01 cannot operate alone.
For low voltage (up to 300V)
Current measurement
POWER CORD
9325
9272-10
9555-10
F/V UNIT 8940
9270, 9271
Use to the 9322 from the F/V UNIT 8940.
* Note that usage restrictions apply.
3272
Not CE certifiedSENSOR UNIT 9555-10
3274
3275
3273-50
3276
CONNECTION CORD 9217
Insulated BNC connectors at
both ends, and connects to
insulated BNC connectors
CONVERSION CABLE 9318 (to connect 9270 - 9272 and 8940)
Not CE certified
Model 9555-10 is required to power the Clamp-On
Sensors, except for connecting Clamp-On Sensor
Model 9270, 9271, 9272-10 to Model 8940, and
for signal output, Model 9217 Connection Cord is
required to connect for input modules.
3269
CLAMP ON SENSOR 9270
5Hz to 50kHz response, up to 20A rms, 2V
AC output
CLAMP ON PROBE 3273-50 CLAMP ON PROBE 3276
DC to 50MHz wideband response,
mA-class current up to 30A rms
DC to 100MHz wideband response,
mA-class current up to 30A rms
CLAMP ON SENSOR 9271
5Hz to 50kHz response, up to 200A rms,
2V AC output
PT 9303
CLAMP ON PROBE 9018-10
Input from 10 to 500A, 40Hz to 3kHz for
0.2V AC output. BNC terminal
Insulation transformer, 400V or
200V AC input, 10V AC output,
for AC power line measurement.
CLAMP ON PROBE 3274
DC to 10MHz wideband response,
mA-class current up to 150A rms
POWER SUPPLY 3272
Connect and power up to one Clamp-On Probes
to use in combination with voltage input modules
(up to two PROBEs restrictively)
CLAMP ON SENSOR 9272-10
1Hz to 100kHz response, selectable 20 and
200A rms ranges, 2V AC output
Not CE certified
CLAMP ON PROBE 9132-10
Input from 20 to 1000A, 40Hz to 1kHz for 0.2V
AC output. BNC terminal, Not CE certified.
CLAMP ON PROBE 3275
DC to 2MHz wideband response,
mA-class current up to 500A rms
CONNECTION CORD 9165
Metal BNC connectors at both
ends, and connects to metal
BNC connectors
POWER SUPPLY 3269
Connect and power up to four Clamp-On Probes
to use in combination with voltage input modules
CONVERSION CABLE 9318
Not CE certified
CLAMP ON LEAK SENSOR 9657-10
For leak current only, 10A for rated current,
40Hz to 5kHz, output rate 100mV/AAC,
BNC terminal
to connect 9270/9271/9272 and 8940
TRIGGER CORD 9305
φ 3.5mm (0.14in) mini-plug, 1.5m
(4.92 ft) length
Supplied with
PC Card
adapter
PC CARD 128M 9726
CONVERSION ADAPTER 9199
Banana-to-BNC, use to connect to
insulation-BNC terminal on Input section
(128 MB capacity)
PC CARD 256M 9727
(256 MB capacity)
PC Card Precaution
PC CARD 512M 9728
Use only PC Cards sold
by HIOKI. Compatibility
and performance are not
guaranteed for PC cards made
by other manufacturers. You
may be unable to read from or
save data to such cards.
(512 MB capacity)
FUNCTION UP DISK 9540-01
DC POWER ADAPTER 9439 CARRYING CASE 9388
Supplies operating power in the range With casters for convenient
PC CARD 1G 9729
For the model 8835-01, use the
FUNCTION UP DISK 9540 with the
the model 8835.
(1 GB capacity)
10 to 28V DC.
transportation.
Printing
Communication
RECORDING PAPER 9221
110 mm (4.33 in) × 30 m (98.43 ft),
10 rolls set
Not CE certified
Not CE certified
LAN COMMUNICATOR 9333 WAVE PROCESSOR 9335
Application software to create a LAN
PAPER WINDER 220H
Paper width 70mm (2.75 in) to
220mm (8.66 in), using special-
purpose AC adapter
LAN CABLE 9642
Supplied with cross conversion
cable, straight Ethernet cable,
length: 5m (16.4ft)
RS-232C CARD 9557 GP-IB CARD 9558
LAN CARD
May not operate depending on the
environment., 10BASE-T
Data conversion, print functions, waveform
connection with Windows 95/98/Me, or display, compatible with Windows 95/98/Me,
PCMCIA-compliant
PCMCIA-compliant, cord
length: 2m (6.6ft)
Windows NT 4.0/2000/XP.
Windows NT 4.0/2000/XP, and Windows
Vista 32-bit type.
■ Combination example: 8835-01 (normal choice of the input unit, up to 200V AC direct input.)
Main unit
8835-01×1
Memory 4MW
standard
2ch
8936×1
9198×2
4ch
8936×2
9198×4
Model number × quantity
Input cable
■ Combination example: 8835-01 (select an automotive input unit that can handle up to 30 V AC.)
Main unit
8835-01×1
Memory 4MW
standard
4ch
8946×1
9198×4
8ch
8946×2
9198×8
Model number × quantity
Input cable
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road
Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
E-mail: info-sh@hioki.cn
DISTRIBUTED BY
Beijing Office :
HEAD OFFICE :
A-2602 Freetown, 58 Dong San Huan Nan Road
Beijing, P.R.China POSTCODE: 100022
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090
E-mail: info-bj@hioki.cn
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: os-com@hioki.co.jp
Guangzhou Office :
HIOKI USA CORPORATION :
Room 303, Profit Plaza, No.76, West Huangpu Road
Guangzhou, P.R.China POSTCODE: 510623
TEL +86-20-38392673/2676 FAX +86-20-38392679
E-mail: info-gz@hioki.cn
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: hioki@hiokiusa.com
All information correct as of Sep. 6, 2007. All specifications are subject to change without notice.
8835-01E11-79B-00P Printed in Japan