5
Model 8731
-10
has two inputs for simultaneous evaluation
of two waveforms
- Operation examples -
Two channels for further enhanced performance
The inputs of Model
8731
-10
(2-channel model) are shown below. The M3.5mm screw terminals are convenient when designing the
wiring layout of a production line. For different requirements, specifications can also be changed to BNC connectors.
(Please contact your
local HIOKI distributor for details.)
For safety, all inputs are isolated from chassis ground and from each other.
Rear view (input terminals)
Front view (2-channel evaluation example)
Evaluation screen can be divided into two windows without impairing resolution
When performing 2-channel evaluation with the
8731
-10
(2-channel model), you can tile the screen horizontally into two sections. On
screen, this means that display resolution is halved, but evaluation precision is not affected. The internal processing memory continues
to perform highly accurate evaluation using the full screen resolution.
When tiling the screen
horizontally, display
resolution is reduced
by a factor of 2, but...
Full screen display example
Tiled screen display example: Evaluation is still performed at
full screen resolution, so there is no drop in accuracy.
Time axis evaluation of X-Y Lissajous waveform and donut-shaped patterns
Because area evaluation is based on screen
display pixels, complex donut-shaped patterns
such as shown at right can also be evaluated.
Evaluation devices from other manufacturers
use A/D conversion and base their area
assessment on digital values. Therefore, they
can only judge whether nor not the upper and
lower limits have been exceeded. Models
8730
-10
and
8731
-10
on the other hand can
also perform FAIL evaluation in the center of
the range, something that is not possible with
competing products.
(X-Y measurement is possible
only with Model
8731
-10
)
Evaluating a time axis waveform using a donut-
shaped area : FAIL evaluation of a pulse with
insufficient amplitude
Using 2-channel input for X-Y Lissajous waveform
evaluation: Vertical and horizontal voltage input allows
Lissajous waveform evaluation.
(Only with Model
8731
-10
)