型号: 3560
PDF下载: 下载PDF文件 查看货源
内容描述: AC毫欧测试仪 [AC mΩ HiTESTER]
分类和应用: 测试
文件页数/大小: 4 页 / 1027 K
品牌: ASM-SENSOR [ ASM GMBH ]
 浏览型号3560的Datasheet PDF文件第1页浏览型号3560的Datasheet PDF文件第2页浏览型号3560的Datasheet PDF文件第4页  
2
High-Speed Measurement Contributing to
Super Efficient Production Lines
Designed for System Use
Utilize the built-in external control terminal to select the
comparator table, as trigger and for requesting printout, etc.
The external output can be used for output of comparator
results, measurement completion (EOC) and NG output. These
external input and output capabilities have been designed with
systems integration in mind.
Timing Chart Example
The following shows a timing example for reading out the
comparator results using the HOLD function and external
input and output features.
Power button
Built-in RS-232C
External control terminal
External output terminal
GP-IB or printer interface
Nature of external control and outputs (negative logic)
Control
(CMOS/5 V max.)
Output
(Open-collector output/35V - 50mA max.)
Measurement trigger (TRIG)
Comparator output request (MANU)
Zero adjustment request (0 ADJ)
Print request (PRINT)
Comparator table selection (COMP)
EXT.DCV (DC5V - 24V)
GND
t1: Approx. 80 ms (FAST 60 Hz), approx. 660 ms (MEDIUM 60 Hz), approx. 1.6s (SLOW 60 Hz)
Approx. 95 ms (FAST 50 Hz), approx. 795 ms (MEDIUM 50 Hz), approx. 1.92s (SLOW 50 Hz)
t2: Approx. 5 ms
t3: Approx. 1 ms
Comparator result signals (Hi, IN,
Lo/PASS, FAIL)
Measurement termination signal
(EOC)
Measurement irregularity detection
signal (NG)
Switch between automatic and manual output of comparator results
(set using panel buttons)
In the HOLD mode, the sequence is simple as EOC is retained until the next
trigger is input. Furthermore, the display and output are retained until the
next EOC is entered.
t1: [Stabilizing time] Following chuck, the trigger is input after the
measuring current has stabilized.
t2: [Detection time]
Time from when chuck is detected until the NG
signal becomes Lo.
* t1 and t2 differ with the measured object. The figures are reference values in case
of pure resistance.
In the AUTO mode, the comparator results are continuously output. In the MANU mode,
the results are only output when the external MANU and GND terminals are shortened.
MANU mode
t3: [Evaluation time]
The time from when the measurement value is
judged at the point when the trigger is input and until
the EOC signal is output. The comparison result is
decided on the rising edge of EOC. At this point, the
evaluation result is obtained.
RS-232C Interface Specifications
Transmission method: Start-stop synchronization, full duplex.
Transmission speed: 9600 bps. Data length: 8 bits. Parity: None. Stop
bit: 1 bit. Handshake: Hardware. Delimiter: CR+LF. Connecting cable:
D-Sub 9-pin female/female connector. Reverse connection.
External Interfaces
(Options)
Install the optional 9588 GP-IB interface to gain full remote
control of the instrument from a PC. Add the 9589 Printer
Interface to enhance the device with printing capabilities via
the 9203 Digital Printer or your own Centronics-based printer.
Connecting the 9203 provides multi-function printing, such
as interval printing, statistical processing of maxima, minima,
average, standard deviation, histogram and graph printing.
9588 GP-IB Interface Specifications
Conforming standard: IEEE-488.1 1987/Reference standard: IEEE-488.2 1987
Print example
9203 Digital Printer Specifications
Printer type: Thermal Line Printer
Statistical processing: Up to 99,999
data points
Histogram and graphics: Up to 5,000
data points
Dimensions and mass: Approx. 215
(W)×160 (H)×54 (D)mm ,1kg / [8.5" (W)
×
6.3" (H)
×
2.1" (D) , 35.3 oz.]
Resistance value histogram
*Note: For further details, please refer to
the product catalog for the HIOKI
3550 Battery HiTESTER series, or
click onto our website at http://
www.hioki.co.jp.
Statistical processing
Resistance value graph printout