< BASIC SPECIFICATIONS
< ENVIRONMENTAL AND SAFETY-RELATED SPECIFICATIONS
Display
4.7-inch color STN LCD
English, Japanese or Chinese (Simplified)
Approx. once per second
Auto calendar, auto leap year, 24-hour format
Within 13 seconds/month
Operating
Indoors, up to 2000 m (6562-ft.) ASL
environment
Display languages
Display refresh rate
Clock functions
Storage
-10 to 50°C (14 to 122°F), 80% RH or less(non-condensating)
Temperature
and humidity
Operation 0 to 40°C (32 to 104°F), 80% RH or less(non-condensating)
EN61010-1: 2001, Pollution degree 2,
Measurement Categories III (600 V) and IV (300 V)
(anticipated transient overvoltage 6000 V)
EN61326:1997 + A1:1998 + A2:2001 + A3:2003 Class
A; EN61000-3-2:2000, EN61000-3-3:1995 + A1:2001
Real-Time Clock accuracy
Safety
EMC
Internal Memory Capacity 4MB
Applicable
standards
Maximum recording time
125 Days
AUTO, 1, 5, 15 and 30 min., and 1 hour (AUTO
sequentially selects 1, 2, 10, 30 seconds, 1, 5, 15
and 30 min., and 1 hour automatically)
Interval Settings
Model 9418-15 AC Adapter or Model 9459 Battery Pack
(Maximum rated power: 23 VA (with AC adapter)
Power source
Demand period
15 min., 30 min. and 1 hour
Continuous
operating time
with battery pack
Approx. 6 hours
(after full charge, with 5 min. auto-off LCD backlight)
Recordable Items
All parameters (incl. max/min/average values)
< INTERFACE SPECIFICATIONS
Interface
Connection destination
128 W × 246 H × 63 D mm (5.04”W × 9.69”H × 2.48”D)
(including stand)
Approx. 1.2 kg (42.3 oz.) (with battery pack)
Dimensions and
mass
USB 2.0 (Full Speed)
Computer operating on Windows 2000/XP
< CLAMP ON SENSOR SPECIFICATIONS
9694
9660
9661
9669
9667
9695-02
9695-03
3m cord
3m cord
3m cord
3m cord
CAT III 1000V
MODEL
2m from sensor to circuit
CAT III 300V
CAT III 300V
φ15mm
CAT III 600V
φ46mm
CAT III 600V
CAT III 300V
CAT III 300V
1m from circuit to connector
Measurable conductor diameter
Primary current rating
Output voltage
Amplitude
φ55mm, 80×20mm
AC 1000A
AC 0.5mV/A
φ254mm
φ15mm
AC 5A
AC 10mV/A
AC 100A
AC 1mV/A
AC 500A
AC 1mV/A
AC 500A/5000A
AC 500mVf.s.
AC 50A
AC 10mV/A
AC 100A
AC 1mV/A
±0.3%rdg.±0.02%f.s. ±0.3%rdg.±0.02%f.s. ±0.3%rdg.±0.01%f.s. ±1.0%rdg.±0.01%f.s. ±2.0%rdg.±1.5mV ±0.3%rdg.±0.02%f.s. ±0.3%rdg.±0.02%f.s.
within ±1°
(45 to 66 Hz)
Accuracy
Phase
(5Hz to 5kHz)
within ±2°
within ±1°
within ±0.5°
within ±1°
within ±2°
within ±1°
(minimum 10% input)
Frequency characteristic
(accuracy deviation)
±3dB at 10Hz to
20kHz
within ±1.0% at 40Hz to 5kHz (9669: within ±2.0%)
within ±1.0% at 40Hz to 5kHz
300Vrms
Max. rated voltage to
earth(insulated conductor)
300Vrms
300Vrms
600Vrms
600Vrms
1000Vrms
Maximum allowable
input (45 to 66 Hz)
50A continuous
130A continuous 550A continuous 1000A continuous 10000A continuous 60A continuous
130A continuous
Dimensions and weight 46W
×
135H
×21Dmm, 230g
46W
×
135H
×21Dmm, 230g
77W
×
151H
×42Dmm, 360g
100W
×
188H
×42Dmm, 590g Sensor length 910mm, 140g
51W×58H×19Dmm, 50g
9445-02/03 AC Adapter (Option)
9219 Connection Cord (3m; Option)
Requirements
9675
9657-10
< COMPLETE LIST OF OPTIONS
9660
9661
9667
9669
9694
CLAMP ON SENSOR (100A)
CLAMP ON SENSOR (500A)
FLEXIBLE CLAMP ON SENSOR (5000A)
CLAMP ON SENSOR (1000A)
CLAMP ON SENSOR (5A)
3m cord
3m cord
MODEL
CAT III 300V
CAT III 300V
Measurable conductor diameter
Primary current rating
Output voltage
φ30mm
AC 10A
φ40mm
AC 10A
9695-02 CLAMP ON SENSOR (50A)
9695-03 CLAMP ON SENSOR (100A)
9219
9657-10 CLAMP ON SENSOR (10A)
9675 CLAMP ON SENSOR (10A)
9438-05 VOLTAGE CORD (bundled with the standard 3197)
9418-15 AC ADAPTER (bundled with the standard 3197)
9459
AC 100mV/A
AC 100mV/A
Amplitude Accuracy
(45 to 66 Hz)
CONNECTION CORD (for the 9695-02/9695-03)
±1.0%rdg.±0.005%f.s.
within ±5°
±1.0%rdg.±0.05%f.s.
within ±3°
Phase Accuracy (50/60Hz)
Residual Current
(10A on forward and return)
(100A on forward and return)
5mA
1mA
Frequency characteristic
(accuracy deviation)
within ±5% at 40Hz to 5kHz within ±3% at 40Hz to 5kHz
300Vrms (insulated conductor)
BATTERY PACK (bundled with the standard 3197)
Max. rated voltage to earth
Maximum allowable input
Dimensions and weight
Notes
9624-50 PQA-HiVIEW Pro PC Application Software (available Fall 2006)
10A continuous
30A continuous
60W×113H×24Dmm, 160g 74W×145H×42Dmm, 380g
Not compatible with power measurements
<3197 STANDARD BUNDLE CONFIGURATION
Includes all the equipment you need to measure voltage.
For current or power measurements, please select from our wide
assortment of clamp on sensors.
<SUGGESTED OPTIONS for POWER MEASUREMENTS
3P4W Circuit testing of motors and breakers:
3197 Standard Package + 9661 (500A Sensor)×3
3P4W Circuit testing of external CTs:
3197 Standard Package + 9694 (5A Sensor)×3
3P Leakage testing:
9438-05 VOLTAGE CORD (3m cord length), 9459 BATTERY PACK, 9418-15
AC ADAPTER, USB Cable, Input Terminal Labels, Input Cord Labels, 3197
Applications PC Program (CD-ROM), strap, carrying case, measurement
guide, instruction manual
3197 Standard Package + 9675 (10A Sensor)×3
DISTRIBUTED BY
HEAD OFFICE :
Shanghai Representative Office :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
1310 Shanghai Times Square Office
TEL +81-268-28-0562 / FAX +81-268-28-0568 93 Huaihai Zhong Road
E-mail: os-com@hioki.co.jp
Shanghai, 200021, P.R.China
TEL +86-21-6391-0090, 0092
FAX +86-21-6391-0360
E-mail: info@hioki.cn
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: hioki@hiokiusa.com
All information correct as of May. 31, 2006. All specifications are subject to change without notice.
3197E1-65E-10K Printed in Japan