欢迎访问ic37.com |
会员登录 免费注册
发布采购

3197 参数 Datasheet PDF下载

3197图片预览
型号: 3197
PDF下载: 下载PDF文件 查看货源
内容描述: 电力质量分析仪 [POWER QUALITY ANALYZER]
分类和应用:
文件页数/大小: 6 页 / 5527 K
品牌: ASM-SENSOR [ ASM GMBH ]
 浏览型号3197的Datasheet PDF文件第1页浏览型号3197的Datasheet PDF文件第2页浏览型号3197的Datasheet PDF文件第3页浏览型号3197的Datasheet PDF文件第4页浏览型号3197的Datasheet PDF文件第6页  
Mobility, Portability Plus  
Convenient Data Transfer  
Right to Your PC  
Feature 4:  
Bundled PC Application  
Software  
Two Integrated Programs for  
Data Download and Viewing  
Feature 5: Compact Design  
Makes for Long Battery Life  
Standard USB connection lets you  
download data at a snap, and  
immediately view your measurements  
with the DataViewer  
6 Hours of Continuous  
Use on a Single Recharge  
Non-volatile Ni-MH rechargeable  
battery pack keeps important  
measurement data in memory  
even after power is turned off.  
Connect to  
multiple 3197 units  
A PQA that TRULY fits in the palm of your hand.  
simultaneously  
using a USB hub  
Standard 3197 Package Fulfills All the Requirements  
for Checking Voltage Anomalies  
Open downloaded recordings with DataViewer to manage  
and process your captured power data on your PC.  
USB Cable  
AC Adapter  
Event List  
Voltage  
Time Plot Graph  
Cords  
Carrying  
Case  
Rechargeable  
Battery Pack  
PC Application  
Event Details  
Event Waveform  
To measure current and power, please select one or more of our  
HIOKI Clamp On Sensors detailed on the back of this catalog.  
Settings  
< Measurement Specifications (Guaranteeed Accuracy Period: 1 Year)  
RMS Voltage and Current True RMS (200 ms calculation )  
Voltage Accuracy ±0.3% rdg. ±0.2%f.s  
< Event Detection  
Voltage Swells (Rise), Voltage RMS value detected using voltage (1/2) measured  
Dips (Drop), Interruptions  
Inrush Current  
Transient Overvoltage  
every half cycle  
RMS value detected using current (1/2) every half cycle  
Detection Range: 50 Vrms (±70.7 Vpeak equiv.) or more, 10 to 100 kHz  
Detect events at preset intervals selectable from  
OFF, 1, 5, 15 or 30 minutes; 1, 2 or 12 hours; or 1 day  
Current Accuracy ±0.3% rdg. ±0.2%f.s. + Clamp sensor accuracy  
Voltage (1/2) RMS  
Measurement  
True RMS  
(one cycle calculation refreshed every half cycle)  
Timer Detection  
Manual Detection  
Accuracy ±0.3% rdg. ±0.2%f.s.  
Detect events when keys are pressed  
Current (1/2) RMS  
Measurement  
True RMS  
Set to OFF or to specified value, except for  
detection of transient overvoltages. (Waveform  
recording not available for transients.)  
(half-cycle calculation, half-cycle voltage synchronized)  
Thresholds  
Accuracy ±0.3% rdg. ±0.2%f.s. + Clamp sensor accuracy  
Effective Measurement range: 45.00 to 66.00 Hz  
Frequency  
Event Recording Lengths  
Accuracy ±0.01 Hz ±1 dgt. (when input is at least 10% of range)  
Waveform 20ms before detection + 200ms upon detection + 20ms after detection  
Event voltage fluctuation graph 0.5s before + 2.5s after detection  
Inrush current graph 0.5s before + 29.5s after detection  
Maximum Number of  
Recordable Events  
Active Power Accuracy  
(for consumption and  
regeneration)  
±0.3% rdg. ±0.2% f.s.  
+ clamp-on sensor accuracy (P.F.=1)  
50 event waveforms, 20 event voltage fluctuation  
graphs, 1 inrush current graph, 1000 event counts  
Reactive Power Accuracy ±1 dgt. of calculation from each measurement  
(for lags and leads) value  
Effect of Power Factor ±1.0% rdg. (50 /60Hz, P.F.=0.5)  
Apparent Power Accuracy ±1 dgt. of calculation from each measurement value  
< Input Specifications  
Single-phase 2-wire (1P2W), single-phase 3-wire  
Power Factor and  
Wiring Configurations  
(1P3W), three-phase 3-wire (3P3W2M and 3P3W3M),  
three-phase four-wire (3P4W and 3P4W2.5E)  
±1 dgt. of calculation from each measurement value  
Displacement Power  
(DPF calculated from phase difference between  
Factor Accuracy  
Measurement Line frequency Auto-select (50/60 Hz)  
fundamental voltage and current waveforms)  
(leading phase indicated)  
Maximum Allowable Input Voltage input terminal: 780 V AC (1103 Vpeak)  
Active or Reactive Energy Selectable between consumption, regeneration,  
Voltage  
Current input terminal: 1.7 V AC (2.4 Vpeak)  
Consumption  
lag and lead  
Maximum Rated Voltage  
to Ground  
Voltage input terminal: CATIII 600 V AC, CATIV 300 V AC (50/60 Hz)  
Current input terminal: per clamp-on sensors used  
±1 dgt. applied to active and reactive power  
measurement accuracy  
Selectable between active or reactive power  
±1 dgt. applied to active and reactive power  
measurement accuracy  
Accuracy  
Accuracy  
Simultaneous digital sampling of voltage and current  
(sampling frequency: 10.24 kHz per channel)  
Measurement Method  
Demand  
Voltage Measurement Range 600.0V (Crest factor 2 or less)  
Clamp Sensor  
9657-10, 9675 500.0 mA/5.000 A 9661, 9667 (500A) 50.00 A/500.0 A  
9694, 9695-02 5.000 A/50.000 A 9669 100.0 A/1.000 kA  
9660, 9695-03 10.00 A/100.0 A 9667 (5000A) 500.0 A/5.000 kA  
500mA 300.0W/600.0W/900.0W 100A 60.00kW/120.0kW/180.0kW  
5A 3.000kW/6.000kW/9.000kW 500A 300.0kW/600.0kW/900.0kW  
Range  
Clamp Sensor  
Range  
Harmonic Analysis Orders Up to 50th (2048 points/window, rectangular)  
Current Measurement  
Range: Manual ranging  
according to clamp sensor  
(Crest factor 3 or less)  
1st to 15th order ±0.5% rdg. ±0.2% f.s.  
Harmonic Voltage,  
16th to 25th order ±1.0% rdg. ±0.3% f.s.  
Current and Power  
26th to 35th order ±2.0% rdg. ±0.3% f.s.  
Accuracy  
36th to 45th order ±3.0% rdg. ±0.3% f.s.  
(accuracy is not defined  
Power Measurement  
Range: Depends on  
46th to 50th order ±4.0% rdg. ±0.3% f.s.  
for harmonic power)  
(add accuracy of clamp sensor to harmonic current accuracy)  
combination of current range  
and measurement line  
10A 6.000kW/12.00kW/18.00kW  
50A 30.00kW/60.00kW/90.00kW  
1kA 600.0kW/1.200MW/1.800MW  
5kA 3.000MW/6.000MW/9.000MW  
Other Measurement  
Items  
Peak Voltage and Current, K Factor, Voltage  
Unbalance Factor, Max/Min/Ave of Time Series  
5