7
■ Settings Display Function
■ Print Function
When you select a data name to be load, the measuring instrument
model and setting conditions at measurement time are displayed.
Measurement data and measurement conditions can be managed
at the same time.
Reports and screen copies of the displayed screen can be easily printed.
Convenient Functions
(1) Printing results can be confirmed by print preview.
(2) When creating a report, screen data can be copied and pasted into a
commercial word processor program.
Preview printing to confirm print results
before printing
Produce daily, weekly or monthly reports by
one-touch report printing
Graph copying is also a one-touch operation
■ 9625 Specifications
■ General Specifications
Supported instrument : 3169-20, 3169-21 and 3166(CLAMP ON POWER HiTESTERs)
models
Supplied Media
: One CD-R disc
Operating environment : Computer: PC-AT compatible (DOS/V machine)
CPU: Pentium 200 MHz or higher
Memory: 128 MB or more (recommended)
Hard disk: 128 MB or more free space
Display: XGA (1024×768) or higher
Disc device: CD-ROM drive (for installation)
Operating system: Windows 2000, XP (English edition)
■ Functional Specifications
[Data/Setting Load/Save Functions]
Loading data /Setting
File extension Data format
Data contents
Instantaneous value, average value, maximum value, minimum value,
integrated value, demand value, harmonic
Data file
CSV
CSV
3169-20/21
Waveform data file
Instantaneous waveform
WUI
BIN
Binary
Binary
CSV
Short-interval data file
Integrated measurement data file
Demand measurement data file
Harmonic measurement data file
Waveform data file
Instantaneous values
Instantaneous value, integrated value
Instantaneous value, maximum value, minimum value, demand value
Instantaneous value, average value, maximum value
Instantaneous waveform
ITG
DEM
HRM
WUI
SET
DAT
CSV
3166
9625
CSV
Binary
–
Setting file
Combined file
Binary
Saved data /Setting
File extension Data format
DAT Binary
Combined file
9625
Maximum data capacity
: Up to 528 MB per data set (total composite data up to 1.5 GB)
[Time Series Graph
Display Function]
Graph display item
:
Voltage, current, active power, reactive power, apparent power,
power factor, frequency, Integrated value(active power, reactive power),
demand, harmonic (level, content ratio, phase angle, total value, THD)
The display position (upper and lower display limits) of the vertical
(Y) axis of a graph can be set by scroll bar or by specifying values.
Select each cycle, or 0.1, 0.2, 0.5, 1, 2, 5, 10, 15 or 30 sec.; 1, 2,
5, 10, 15 or 30 min.; or 1, 2, 3, 4, 6, 8 or 12 h; or 1 day
An optional analysis period can be specified from the overall
measurement data period
Reference value setting
Graph type selection
Graph line type & color
setting
Stacked bar graph
display
: Display set standard value
: Line, bar, 2-axes and 3-dimensional
: Line type and display color can be set for each data set,
and marker display is possible
Y-axis upper/lower
limit setting
Interval setting
:
:
:
:
Up to 16 types of data series (demand value, demand quantity )
can be displayed in an overlay graph
Display period range
setting
Cursor measurement
Data display units setting
:
Measurement values can be displayed by the cursor
: Engineering units (m, k, M, G, etc.) can be selected
(1) Analysis start date and time (YMD, HMS) is specified numerically
(2) Analysis stop date and time (YMD, HMS) is specified numerically
Display of measurement data period (measurement start
and stop date and time)