CXE15 Single Series | 10.8 to 15W DC/DC  
High Efficiency DC/DC converters  
EMC  
Electromagnetic Compatibility  
Phe nom e non  
Emission:  
Port  
Standard  
Te st le ve l Crite ria  
Note s and conditions  
Conducted  
DC power  
EN55022  
Level A  
Level B  
With recommended external filter for  
compliance bandwidth 20 kHz to 30 MHz,  
as per ETS 300 386-1. See Application  
Note 116 for details  
EN55022  
With recommended external filter for  
compliance bandwidth 20 kHz to 30 MHz,  
as per ETS 300 386-1. See Application  
Note 116 for details  
Signal  
EN55022  
EN55022  
Level B  
Level B  
Bandwidth 150kHz to 30MHz,  
as per ETS 300 386-1  
Radiated  
Bandwidth 30 MHz to 1 GHz, as per  
ETS 300 386-1  
Performance criteria:  
NP: Normal Performance: EUT shall withstand applied test and operate within relevant limits as specified without damage.  
RP: Reduced Performance: EUT shall withstand applied test. Reduced performance is permitted within specified limits, resumption to  
normal performance shall occur at the cessation of the test.  
LFS: Loss of Function (self recovery): EUT shall withstand applied test without damage, temporary loss of function permitted during test.  
Unit will self recover to normal performance after test.  
Referenced ETSI standards:  
ETS 300 386-1 table 5 (1997): Public telecommunication network equipment, EMC requirements  
ETS 300 132-2 (1996): Power supply interface at the input to telecommunication equipment: Part 2 operated by direct current (DC)  
ETR 283 (1997): Transient voltages at interface A on telecommunication direct current (DC) power distributions  
Standards Compliance List  
Standard  
Cate gory  
EN60950  
2000  
UL/cUL 1950  
TÜV Rheinland  
3rd edition  
EN60950:2000  
Safety Agency Approvals  
Characte ristic  
UL/cUL 1950 File Number  
E135734  
TÜV Rheinland Certificate No.  
R2074133  
Material Ratings  
Characte ristic - Signal Nam e Note s and Conditions  
Flammability rating  
Material type  
UL94V-0  
FR4 PCB  
Model Numbers  
Mode l  
Input  
Output  
Voltage  
Ove rvoltage  
Prote ction  
Output Curre nt  
(Max.)  
Typical  
Max. Load  
Re gulation  
Num be r  
Voltage  
Efficie ncy  
CXE15-48S1V8  
CXE15-48S2V5  
CXE15-48S3V3  
CXE15-48S05  
33-75 VDC  
33-75 VDC  
33-75 VDC  
33-75 VDC  
1.8V  
2.5V  
3.3V  
5.0V  
2.3V  
3.2V  
4.0V  
6.0V  
6.0A  
6.0A  
4.5A  
3.0A  
83%  
85%  
86%  
87%  
2.0%  
1.5%  
0.5%  
0.5%  
5
www.artesyn.com