SXA10 Series
| 15W DC/DC
CXE15 Single Series | 10.8 to 15W DC/DC
High Efficiency DC/DC converters
Other Specifications
Characte ristic
Sym bol
Min
Typ
265
12
Max
Units
kHz
g
Note s and Conditions
Switching frequency
Weight
F
Fixed frequency
sw
Environmental Specifications
Characte ristic
Sym bol
Min
Typ
Max
Units
Note s and Conditions
Thermal performance
1V8 and 2V5 models
3V5 and 5V models
-40
-40
70
65
ºC
ºC
See Notes 1, 4 and
individual derating curves
Type
Param e te r
Re fe re nce
Te st Le ve l
Note s and Conditions
Air temperature
Low
IEC 68-2-1
IEC 68-2-2
IEC 68-2-14
-40ºC
+70ºC
All characteristics and parameters
extracted from ETS 300 019
classes 3.1, 3.2, 3.3, 3.4 and 3.5
High
Change
-40ºC to +70ºC
T
= +70˚C for T3.4
max.
Relative humidity
Low
-
10%
High
IEC 68-2-56
IEC 68-2-30
100%
Condensation
90 to 100%
Vibration IEC Class 3M5
Shocks IEC Class 3M5
Freq. velocity
IEC 68-2-6
5-9Hz 5mm/s
9-200Hz 1g
Freq. acceleration IEC 68-2-6
Acceleration IEC 68-2-29
10g
Referenced ETSI standards:
ETS 300 019: Environmental conditions and environmental tests for telecommunications equipment
ETS 300 019: Part 1-3 (1997) Classification of environmental conditions stationary use at weather protected locations
ETS 300 019: Part 2-3 (1997) Specification of environmental tests stationary use at weather protected locations
EMC
Electromagnetic Compatibility
Phe nom e non
Immunity:
ESD
Port
Standard
Te st le ve l
Crite ria
Note s and conditions
Enclosure
EN61000-4-2 6kV contact
8kV air
As per ETS 300 386-1 table 5
EFT
DC power
Signal
EN61000-4-4 2kV
As per ETS 300 386-1 table 5
As per ETS 300 386-1 table 5
4kV
EN61000-4-4 1kV
2kV
Radiated field
Conducted
Enclosure
EN61000-4-3 10V/m
As per ETS 300 386-1 table 5
DC power
Signal
EN61000-4-6 10V
EN61000-4-6 10V
As per ETS 300 386-1 table 5
Signal line assumed < 3m in length
Input transients
DC power
ETS 300 132, ETR 283
4