Technical Reference Note
Output Specifications
Rev.07.04.14_#1.0
AVO100-36S3V3B-6L
Page 6
Table 3. Output Specifications, con’t:
Parameter
Condition
Symbol
Min
3.5
-0.7
-
Typ
Max
Unit
V
Off-statevoltage
On-state voltage
All
All
All
All
All
-
12
1.2
Remote ON/OFF
control (Negative logic)
-
V
Output voltage remote sense range
Output over-voltageprotection3
Output over-temperatureprotection4
-
-
0.165
4.6
V
VO
T
3.8
-
V
110
125
OC
Telcordia SR-332
Method 1 Case3; 80%
load, 300LFM, 40 OC
TA
MTBF
-
1.5
-
106 h
Note 3 - Hiccup: auto-restart when over-voltage condition is removed.
Note 4 - Auto recovery.