CS5480
3. CHARACTERISTICS AND SPECIFICATIONS
RECOMMENDED OPERATING CONDITIONS
Parameter
Positive Analog Power Supply
Symbol
VDDA
Min
3.0
Typ
3.3
-
Max
Unit
V
3.6
Specified Temperature Range
T
-40
+85
°C
A
POWER MEASUREMENT CHARACTERISTICS
Parameter
Symbol
Min
Typ
Max
Unit
Active Energy
All Gain Ranges
Current Channel Input Signal Dynamic Range 4000:1
P
-
-
-
-
-
-
±0.1
±0.1
±0.1
±0.1
±0.1
±0.1
-
%
Avg
(Note 1 and 2)
Reactive Energy
(Note 1 and 2)
All Gain Ranges
Current Channel Input Signal Dynamic Range 4000:1
Q
-
-
-
-
-
%
%
%
%
%
Avg
Apparent Power
(Note 1 and 3)
All Gain Ranges
Current Channel Input Signal Dynamic Range 1000:1
S
Current RMS
(Note 1, 3, and 4)
All Gain Ranges
Current Channel Input Signal Dynamic Range 1000:1
I
RMS
Voltage RMS
(Note 1 and 3)
V
RMS
Voltage Channel Input Signal Dynamic Range 20:1
Power Factor
(Note 1 and 3)
All Gain Ranges
Current Channel Input Signal Dynamic Range 1000:1
PF
Notes: 1. Specifications guaranteed by design and characterization.
2. Active energy is tested with power factor (PF) = 1.0. Reactive energy is tested with Sin() = 1.0. Energy error measured at system
level using a single energy pulse. Where: 1) One energy pulse = 0.5Wh or 0.5Varh; 2) VDDA = +3.3V, TA = 25°C, MCLK =
4.096MHz; 3) System is calibrated.
3. Calculated using register values; N≥4000.
4. IRMS error calculated using register values. 1) VDDA = +3.3V; TA = 25°C; MCLK = 4.096MHz; 2) AC offset calibration applied.
TYPICAL LOAD PERFORMANCE
• Energy error measured at system level using single energy pulse; where one energy pulse = 0.5Wh or 0.5Varh.
• IRMS error calculated using register values.
• VDDA = +3.3V; TA = 25°C; MCLK = 4.096MHz.
1
0.5
0
-0.5
-1
Lagging PF = 0.5
Leading PF = 0.5
PF = 1
0
500
1000
1500
2000
2500
3000
3500
4000
4500
Current Dynamic Range (x : 1
)
Figure 4. Active Energy Load Performance
DS980F2