CS5480  
3. CHARACTERISTICS AND SPECIFICATIONS  
RECOMMENDED OPERATING CONDITIONS  
Parameter  
Positive Analog Power Supply  
Symbol  
VDDA  
Min  
3.0  
Typ  
3.3  
-
Max  
Unit  
V
3.6  
Specified Temperature Range  
T
-40  
+85  
°C  
A
POWER MEASUREMENT CHARACTERISTICS  
Parameter  
Symbol  
Min  
Typ  
Max  
Unit  
Active Energy  
All Gain Ranges  
Current Channel Input Signal Dynamic Range 4000:1  
P
-
-
-
-
-
-
±0.1  
±0.1  
±0.1  
±0.1  
±0.1  
±0.1  
-
%
Avg  
(Note 1 and 2)  
Reactive Energy  
(Note 1 and 2)  
All Gain Ranges  
Current Channel Input Signal Dynamic Range 4000:1  
Q
-
-
-
-
-
%
%
%
%
%
Avg  
Apparent Power  
(Note 1 and 3)  
All Gain Ranges  
Current Channel Input Signal Dynamic Range 1000:1  
S
Current RMS  
(Note 1, 3, and 4)  
All Gain Ranges  
Current Channel Input Signal Dynamic Range 1000:1  
I
RMS  
Voltage RMS  
(Note 1 and 3)  
V
RMS  
Voltage Channel Input Signal Dynamic Range 20:1  
Power Factor  
(Note 1 and 3)  
All Gain Ranges  
Current Channel Input Signal Dynamic Range 1000:1  
PF  
Notes: 1. Specifications guaranteed by design and characterization.  
2. Active energy is tested with power factor (PF) = 1.0. Reactive energy is tested with Sin() = 1.0. Energy error measured at system  
level using a single energy pulse. Where: 1) One energy pulse = 0.5Wh or 0.5Varh; 2) VDDA = +3.3V, TA = 25°C, MCLK =  
4.096MHz; 3) System is calibrated.  
3. Calculated using register values; N4000.  
4. IRMS error calculated using register values. 1) VDDA = +3.3V; TA = 25°C; MCLK = 4.096MHz; 2) AC offset calibration applied.  
TYPICAL LOAD PERFORMANCE  
• Energy error measured at system level using single energy pulse; where one energy pulse = 0.5Wh or 0.5Varh.  
• IRMS error calculated using register values.  
• VDDA = +3.3V; TA = 25°C; MCLK = 4.096MHz.  
1
0.5  
0
-0.5  
-1  
Lagging PF = 0.5  
Leading PF = 0.5  
PF = 1  
0
500  
1000  
1500  
2000  
2500  
3000  
3500  
4000  
4500  
Current Dynamic Range (x : 1  
)
Figure 4. Active Energy Load Performance  
DS980F2  