CS1630/31
6.39 Configuration 58 (Config58) – Address 90
7
6
5
4
3
2
1
0
SHUTDWN3 SHUTDWN2 SHUTDWN1 SHUTDWN0
LOW_SAT2
LOW_SAT1
LOW_SAT0
DIM_TEMP
Number
Name
Description
Configures the 8-bit code value corresponding to temperature threshold
Temp . If the temperature exceeds this threshold, the device enters an
Shutdown
external overtemperature state and shuts down.
[7:4]
SHUTDWN[3:0]
CODETEMPShutdown = CODETEMPWakeup + SHUTDWN[3:0] 4
The wakeup temperature code is configured as an offset from the eOTP tem-
perature code and the shutdown temperature code is configured as an offset
from the wakeup temperature code; Temp
< Temp
< Temp
eOTP
Wakeup Shutdown
Sets the lower saturation limit for the 8-bit temperature code provided to the
color system from the fast low pass filter before it is used for polynomial com-
putations.The lower saturation limit is given by:
[3:1]
LOW_SAT[2:0]
DIM_TEMP
LOW_SAT[2:0] + 1 5
Configures the external overtemperature protection (eOTP) dim with tempera-
ture feature, which decreases the second stage dim level once the tempera-
ture measured using the external NTC connected to pin eOTP exceeds the
temperature threshold set using eOTP[4:0], Temp
(see “Configuration 59
[0]
eOTP
(Config59) – Address 91” on page 48).
0 = Disable
1 = Enable
6.40 Configuration 59 (Config59) – Address 91
7
6
5
4
3
2
1
0
eOTP4
eOTP3
eOTP2
eOTP1
eOTP0
HI_SAT2
HI_SAT1
HI_SAT0
Number
Name
Description
Configures 8-bit code value CODE corresponding to the tempera-
TEMPeOTP
ture Temp
enabled.
set point at which the eOTP dim with temperature feature is
eOTP
[7:3]
eOTP[4:0]
CODETEMPeOTP = 80 + eOTP[4:0] 4
Sets the higher saturation limit for the 8-bit temperature code provided to the
color system before it is used for polynomial computations.
000 = CODE
TEMPShutdown
001 = 100
010 = 120
011 = 140
100 = 160
101 = 180
110 = 200
111 = 220
[2:0]
HI_SAT[2:0]
48