CS1630/31  
6.32 Configuration 50 (Config50) Address 82  
7
6
5
4
3
2
1
0
OVP_CNT2  
OVP_CNT1  
OVP_CNT0  
OVP_LAT  
OVP_TYPE OVP_BLANK2 OVP_BLANK1 OVP_BLANK0  
Number  
Name  
Description  
Sets the second stage OVP fault counter threshold used when declaring a  
fault.  
[7:5]  
[4]  
OVP_CNT[2:0]  
OVP_LAT  
0 = Force OVP fault (debug only)  
1-7 = Number of times an OVP fault has to occur consecutively before  
the IC will enter a fault state.  
Configures second stage OVP fault type.  
0 = Unlatched fault  
1 = Latched fault  
Selects the type of blanking for the second stage OVP. When bit  
OVP_TYPE is set to T2 offset, the blanking time is always equal to the cor-  
responding channel’s previous T2 switching cycle time minus an offset of  
500ns.  
[3]  
OVP_TYPE  
0 = Fixed time blanking mode  
1 = T2 offset blanking mode.  
Configures fixed time blanking interval t  
for output open protection,  
OVP  
OVP. The value is an unsigned integer in the range of 0value7.  
tOVP = 1s + OVP_BLANK[2:0] 0.5s  
[2:0]  
OVP_BLANK[2:0]  
6.33 Configuration 51 (Config51) Address 83  
7
6
5
4
3
2
1
0
RESTART5  
RESTART4  
RESTART3  
RESTART2  
RESTART1  
RESTART0 FAULT_SLOW FAULT_SHDN  
Number  
Name  
Description  
for second stage faults that are set as unlatched  
Set fault restart time T  
Restart  
type. If slow restart bit FAULT_SLOW is enabled, then  
TRestart = RESTART[5:0] 40.96ms  
[7:2]  
RESTART[5:0]  
else  
TRestart = RESTART[5:0] 25.6s  
Configures slow restart for second stage faults that are set at unlatched type.  
0 = Disable slow restart; use 25.6s timer for restart time countdown  
1 = Enable slow restart; use 40.96ms timer for restart time countdown  
[1]  
FAULT_SLOW  
FAULT_SHDN  
Selects which stages to disable when a fault event occurs in the second stage.  
0 = Shutdown second stage only  
[0]  
1 = Shutdown boost stage and second stage  
DS954F2  
43