CS1630/31
6.29 Configuration 47 (Config47) – Address 79
7
6
5
4
3
2
1
0
OCP
OLP
OVP
BOP
COP
LLP
EEOTP
IOTP
Number
Name
Description
Configures second stage primary side overcurrent protection.
[7]
OCP
0 = Enable
1 = Disable
Configures second stage primary side open loop protection (R
Short Pro-
Sense
tection).
[6]
OLP
0 = Enable
1 = Disable
Configures second stage secondary side overvoltage protection (Output Open
Circuit Protection).
0 = Enable
[5]
OVP
1 = Disable
Configures boost overvoltage protection.
[4]
[3]
[2]
[1]
[0]
BOP
COP
0 = Enable
1 = Disable
Configures clamp overpower protection.
0 = Enable
1 = Disable
Configures line link protection.
0 = Enable
LLP
1 = Disable
Configures external overtemperature protection.
EEOTP
IOTP
0 = Enable
1 = Disable
Configures internal overtemperature protection.
0 = Enable
1 = Disable
DS954F2
41