CS1630/31  
PLC Start Char  
Special Char  
‘00’  
‘01’  
90°  
90°  
34°  
90°  
34°  
62°  
‘11’  
‘10’  
PLC Stop Char  
146°  
118°  
90°  
146°  
90°  
Figure 24. Power Line Calibration Mode Character Waveforms  
5.10.2 PLC Program Mode Characters  
Name  
OPCODE  
0000  
0001  
0010  
0011  
Description  
In order to program the CS1630/31, a set of encoded  
characters is built from specific phase-cut waveform patterns.  
Figure 24 illustrates the phase-cut waveform encoding  
recognized by the CS1630/31 power line calibration system.  
As shown in Table 1, six characters are formed using the  
special character and two-bit encoded data.  
NOP  
No Operation  
INIT_PROG_MODE  
I2C_WRITE  
Initialize program mode(1)  
Perform a generic I2C write  
Reserved  
Initiate an OTP write cycle(3)  
Write String 1 offset(2)  
Write String 2 offset(2)  
Write CRC value  
BURN_OTP  
0100  
0101  
0110  
Character  
Start Char  
Code  
Notes  
PLC Program Start Character(1)  
PLC Program Stop Character(1)  
2-bit Data [00]  
STR1_OFFSET  
STR2_OFFSET  
WRITE_CRC  
(SC)00(SC)  
Stop Char  
(SC)11(SC)  
0111  
Duo-bit ‘00’  
Duo-bit ‘01’  
Duo-bit ‘10’  
Duo bit ‘11’  
00  
01  
10  
11  
END_PROG_MODE  
WRITE_DIM  
1000  
1001  
Disable programming mode  
Sets PLC dim value  
2-bit Data [01]  
2-bit Data [10]  
Notes: (1) Allows other commands to program the device under test.  
(2) Range of Offset tolerance is ±15%.  
2-bit Data [11]  
(3) The light is flashed to indicate pass or fail.  
Note: (1) A Special Character (SC) must precede and follow the Duo-bit.  
Table 2. Power Line Calibration Operation Code  
Table 1. Power Line Calibration Characters  
The LED light flashes seven times to indicate a command  
error. The LED flashes two times when OTP registers are  
programmed successfully and four times when programming  
is unsuccessful. Figure 25 illustrates an example of a power  
line calibration mode command sequence and the cut-  
waveform pattern.  
5.10.3 Calibration Mode Operation Code  
The CS1630/31 power line calibration system requires a start  
and stop operation code to activate and deactivate power line  
calibration mode. Once in the power line calibration mode,  
operation codes (OPCODE) will be used to program specific  
addresses using the OPCODE listed in Table 2.  
Calibration Command Sequence  
Start Char [(SC)00(SC)]  
Addr Bcast  
&
OPCODE  
[2 Duo-bits]  
Odd Parity  
&
Stop Char [(SC)11(SC)]  
Simple Code  
[1 Duo-bit]  
Don’t Care  
[1 Duo-bit]  
Before Transmit  
PLC Start Character  
Addr Bcast  
PLC Operation Code  
Odd Parity  
PLC Stop Character  
After Transmit  
&
Simple Code  
00  
(4-bit)  
0000  
&
Don’t Care  
10  
135°  
135°  
90°  
34°  
90°  
34°  
34°  
34°  
118°  
90°  
146°  
90°  
135°  
135°  
Figure 25. Power Line Calibration Mode Example  
22  
DS954F2