Application Descriptions (Cont.)  
Thermal Pad Considerations (Cont.)  
internal dissipation figures are taken from the Power  
Dissipation vs. Output Power graphs.  
TAMax = TJMax -qJAPD  
design issues are not properly addressed, the  
APA2068 4W will go into thermal shutdown when  
driving a 4W load.  
(16)  
150 - 45(0.8*2) = 78°C  
The thermal padon thebottom of theAPA2068should  
be soldered down to a copper padon thecircuit board.  
Heat can be conducted away from the thermal pad  
throughthecopperplanetoambient. If thecopperplane  
is not on the top surface of the circuit board, 8 to 10  
vias of 13 mil or smaller in diameter should be used to  
thermally couple the thermal pad to the bottom plane.  
The APA2068 is designed with a thermal shutdown  
protection that turns the device off when the junction  
temperaturesurpasses150°Ctopreventdamagingthe  
IC.  
For good thermal conduction, the vias must be plated  
through and solder filled. The copper plane used to  
conduct heat away from the thermal pad should be as  
large as practical.  
If the ambient temperatureishigher than25°C, a larger  
copper plane or forced-air cooling will be required to  
keep the APA2068 junction temperature below the  
thermal shutdown temperature (150°C). In higher  
ambient temperature, higher airflow rate and/or larger  
copper area will be required to keep the IC out of  
thermal shutdown.  
Thermal Considerations  
Linear power amplifiers dissipate a significant amount  
of heat in the package under normal operating  
conditions.  
To calculate maximum ambient temperatures, first  
consideration is that the numbers from the Power  
Dissipation vs. Output Power graphs are per  
channel values, sothe dissipation of theIC heat needs  
tobedoubledfor two-channel operation.GivenqJA, the  
maximum allowable junction temperature (TJMAX), and  
the total internal dissipation (PD), the maximum  
ambient temperature can be calculated with the  
following equation. The maximum recommended  
junction temperature for the APA2068 is 150°C. The  