欢迎访问ic37.com |
会员登录 免费注册
发布采购

AAT2846 参数 Datasheet PDF下载

AAT2846图片预览
型号: AAT2846
PDF下载: 下载PDF文件 查看货源
内容描述: 高电流电荷泵,带有双LDO用于背光和闪光应用 [High Current Charge Pump with Dual LDO for Backlight and Flash Applications]
分类和应用:
文件页数/大小: 25 页 / 646 K
品牌: ANALOGICTECH [ ADVANCED ANALOGIC TECHNOLOGIES ]
 浏览型号AAT2846的Datasheet PDF文件第11页浏览型号AAT2846的Datasheet PDF文件第12页浏览型号AAT2846的Datasheet PDF文件第13页浏览型号AAT2846的Datasheet PDF文件第14页浏览型号AAT2846的Datasheet PDF文件第16页浏览型号AAT2846的Datasheet PDF文件第17页浏览型号AAT2846的Datasheet PDF文件第18页浏览型号AAT2846的Datasheet PDF文件第19页  
AAT2846  
High Current Charge Pump with Dual LDO  
for Backlight and Flash Applications  
Backlight Independent Channel Control  
(Address 15)  
The AAT2846 has a unique independent channel  
control mode whereby individual backlight LED  
channels can be enabled and disabled to form a  
custom arrangement of active channels.  
Data  
1
2
3
4
5
6
7
8
BL6  
BL5  
BL4  
BL3  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
To enable independent channel control mode, write  
Data 8 to Address 15. To exit individual mode con-  
trol, the AAT2846 state machine can be reset by  
strobing ENS low and holding ENS low longer than  
9
2
the A SCwire's tOFF latch time.  
10  
11  
12  
13  
14  
15  
16  
Data  
Individual Backlight Control  
8
On  
Table 7: Data Code for Independent  
Backlight Control, Address 15.  
With independent channel control mode enabled,  
Addresses 2 and 3 are re-mapped according to  
Tables 8 and 9. As indicated by the possible set-  
tings listed in the tables, any combination of back-  
lighting channels can be enabled and disabled.  
Table 8: Data Code for BL3-BL6  
On/Off Control, Sub-Address 2.  
Data  
BL2  
BL1  
Because Addresses 2 and 3 are re-mapped when  
independent channel control mode is enabled, the  
functions originally assigned to Addresses 2 and 3  
are no longer available.  
It is also important to note that Address 0 is dis-  
abled when independent channel control mode is  
enabled. Additionally, Address 3 is disabled and the  
very low current settings cannot be used in this  
mode. Other addresses are unmodified by this  
mode so that the flash features can still be operat-  
ed and the 30mA backlight scale can still be used.  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
The LDO enables are always independent of  
2
AS Cwire programming.  
Flash LED Current Control  
The flash LEDs are driven through current sinks  
FL1 and FL2. There are two ways to drive the flash  
2
Table 9: : Data Code for BL1 and BL2  
On/Off Control, Sub-Address 3.  
LEDs: either through the AS Cwire serial interface  
or through the flash enable input, FEN. The  
AAT2846 also includes an adjustable safety timer  
to turn off the flash in the event of a controller fault  
to prevent overstressing the flash LEDs.  
Flash/Movie Mode Operation  
The flash LED current level is set via the serial inter-  
face according to a logarithmic scale where each  
code is 1.2dB lower than the previous code as a per-  
2846.2007.08.1.0  
15