欢迎访问ic37.com |
会员登录 免费注册
发布采购

AAT2846 参数 Datasheet PDF下载

AAT2846图片预览
型号: AAT2846
PDF下载: 下载PDF文件 查看货源
内容描述: 高电流电荷泵,带有双LDO用于背光和闪光应用 [High Current Charge Pump with Dual LDO for Backlight and Flash Applications]
分类和应用:
文件页数/大小: 25 页 / 646 K
品牌: ANALOGICTECH [ ADVANCED ANALOGIC TECHNOLOGIES ]
 浏览型号AAT2846的Datasheet PDF文件第10页浏览型号AAT2846的Datasheet PDF文件第11页浏览型号AAT2846的Datasheet PDF文件第12页浏览型号AAT2846的Datasheet PDF文件第13页浏览型号AAT2846的Datasheet PDF文件第15页浏览型号AAT2846的Datasheet PDF文件第16页浏览型号AAT2846的Datasheet PDF文件第17页浏览型号AAT2846的Datasheet PDF文件第18页  
AAT2846  
High Current Charge Pump with Dual LDO  
for Backlight and Flash Applications  
Flash Current FL1, FL2 (Address 4)  
Independent Flash ON/OFF Control  
(Address 5)  
The current level for the flash channels FL1 and  
FL2 is programmed by Address 4. Data 1 enables  
the maximum current level. The maximum current  
level is determined by the value of RFSET. Table 4  
and Figure 3 illustrate the additional flash current  
levels that are available.  
Use Address 5 to program which flash channels  
are active. By default, both flash channels are OFF  
at startup. After writing to Address 4 to program the  
desired flash channel current level, write to  
Address 5 to enable a single channel or both chan-  
nels according to Table 5.  
Flash LED Current  
Data  
(% of Maximum)  
Data  
FL1  
FL2  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
100  
87  
77  
66  
58  
50  
44  
39  
35  
30  
27  
24  
20  
17  
16  
14  
1
2
3
4
Off  
Off  
On  
On  
Off  
On  
Off  
On  
Table 5: Output Enable Control, Address 5.  
Writing to Address 5 enables the flash channels  
indefinitely. FL1 and FL2 will remain ON until  
Address 5 is re-programmed to OFF, ENS is  
strobed low to shutdown the device, or the flash  
safety timer times out after FEN has been strobed  
high. The flash safety timer is always activated  
when FEN is taken high. The Address 5 data set-  
ting is always reset to Data 1 when the flash timer  
expires or when FEN is strobed low.  
Maximum Backlight Current (Address 12)  
Table 4: Data Code for the Flash Current  
Control, Address 4.  
There are two separate current level scales that apply  
to Addresses 0-2: 20mA and 30mA. According to the  
Maximum Backlight Current setting at Address 12,  
only one of the two scales can be active at any given  
time and never both. By default, the 20mA scale is  
active on startup. To change to the 30mA scale, or go  
back to the 20mA scale, write to Address 12.  
120  
IFLED = 100%  
at Data 1  
100  
80  
60  
Since only one of the scales can be active at any  
given time, the 20mA and 30mA scales cannot be  
mixed between main and sub. When setting Address  
12 to the 30mA scale, only current levels from that  
scale can be mixed between main and sub.  
IFLED = 14%  
40  
at Data 16  
20  
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16  
Data Code  
Data  
1
2
Maximum Current  
Figure 3: Data Code for Address 4 vs.  
percentage of Flash Current Level.  
20mA  
30mA  
Table 6: Data Code for the Maximum Current  
Settings, Address 12.  
14  
2846.2007.08.1.0