欢迎访问ic37.com |
会员登录 免费注册
发布采购

AAT2515IWP-AA-T1 参数 Datasheet PDF下载

AAT2515IWP-AA-T1图片预览
型号: AAT2515IWP-AA-T1
PDF下载: 下载PDF文件 查看货源
内容描述: 两个600mA快速瞬态高频降压转换器 [Dual 600mA Fast Transient High Frequency Buck Converter]
分类和应用: 转换器
文件页数/大小: 20 页 / 616 K
品牌: ANALOGICTECH [ ADVANCED ANALOGIC TECHNOLOGIES ]
 浏览型号AAT2515IWP-AA-T1的Datasheet PDF文件第9页浏览型号AAT2515IWP-AA-T1的Datasheet PDF文件第10页浏览型号AAT2515IWP-AA-T1的Datasheet PDF文件第11页浏览型号AAT2515IWP-AA-T1的Datasheet PDF文件第12页浏览型号AAT2515IWP-AA-T1的Datasheet PDF文件第14页浏览型号AAT2515IWP-AA-T1的Datasheet PDF文件第15页浏览型号AAT2515IWP-AA-T1的Datasheet PDF文件第16页浏览型号AAT2515IWP-AA-T1的Datasheet PDF文件第17页  
PRODUCT DATASHEET  
AAT2515  
SystemPowerTM  
Dual 600mA FastTransient High Frequency Buck Converter  
3. The feedback trace should be separate from any  
power trace and connect as closely as possible to the  
PCB Layout  
The following guidelines should be used to insure a  
proper layout.  
load point. Sensing along a high-current load trace  
will degrade DC load regulation. If external feedback  
resistors are used, they should be placed as closely  
as possible to the FB pin. This prevents noise from  
being coupled into the high impedance feedback  
node.  
1. Due to the pin placement of VIN for both converters,  
proper decoupling is not possible with just one input  
capacitor. The large input capacitor C3 should con-  
nect as closely as possible to VIN and GND, as shown  
in Figure 2. The additional input bypass capacitor C8  
is necessary for proper high frequency decoupling of  
the second converter.  
2. The output capacitor and inductor should be con-  
nected as closely as possible. The connection of the  
inductor to the LX pin should also be as short as  
possible.  
4. The resistance of the trace from the load return to  
GND should be kept to a minimum. This will help to  
minimize any error in DC regulation due to differ-  
ences in the potential of the internal signal ground  
and the power ground.  
5. For good thermal coupling, PCB vias are required  
from the pad for the TDFN paddle to the ground  
plane. The via diameter should be 0.3mm to 0.33mm  
and positioned on a 1.2 mm grid.  
w w w . a n a l o g i c t e c h . c o m  
2515.2007.12.1.0  
13