欢迎访问ic37.com |
会员登录 免费注册
发布采购

AWT6221R_10 参数 Datasheet PDF下载

AWT6221R_10图片预览
型号: AWT6221R_10
PDF下载: 下载PDF文件 查看货源
内容描述: HELP3双波段蜂窝/ PCS UMTS 3.4 V HSPA线性功率放大器模块 [HELP3 Dual-band Cellular/PCS UMTS 3.4 V HSPA Linear Power Amplifier Module]
分类和应用: 放大器功率放大器过程控制系统PCS蜂窝
文件页数/大小: 8 页 / 583 K
品牌: ANADIGICS [ ANADIGICS, INC ]
 浏览型号AWT6221R_10的Datasheet PDF文件第1页浏览型号AWT6221R_10的Datasheet PDF文件第2页浏览型号AWT6221R_10的Datasheet PDF文件第3页浏览型号AWT6221R_10的Datasheet PDF文件第5页浏览型号AWT6221R_10的Datasheet PDF文件第6页浏览型号AWT6221R_10的Datasheet PDF文件第7页浏览型号AWT6221R_10的Datasheet PDF文件第8页  
AWT6221R  
Table 4: Electrical Specifications - Cellular Band  
(T  
C
= +25 °C, VBATT = VCC = +3.4 V, VENABLE = +2.4 V, 50 system)  
COMMENTS  
PARAMETER  
MIN  
TYP  
MAX  
UNIT  
P
OUT  
V
MODE1  
24.5  
13.5  
27  
15.5  
29.0  
18.0  
+29 dBm  
+16 dBm  
0 V  
2.4 V  
Gain  
dB  
dBc  
dBc  
%
-
-
-41  
-44  
-37.5  
-38  
+29 dBm  
+16 dBm  
0 V  
2.4 V  
ACLR1 at 5 MHz offset (1)  
ACLR2 at 10 MHz offset  
Power-Added Efficiency (1)  
-
-
-60  
-57  
-48  
-48  
+29 dBm  
+16 dBm  
0 V  
2.4 V  
38  
18  
42  
22  
-
-
+29 dBm  
+16 dBm  
0 V  
2.4 V  
Quiescent Current (Icq)  
Mode Control Current  
Enable Current  
5
-
8
13  
0.8  
0.8  
5
mA  
mA  
mA  
mA  
VMODE1 = +2.4 V  
0.35  
0.5  
2.5  
through VMODE1 pin, VMODE = +2.4 V  
through VENABLE pin  
-
BATT Current  
-
through VBATT pin, VMODE1 = +2.4 V  
V
V
BATT = +4.2 V, VCC = +4.2 V,  
ENABLE = 0 V, VMODE1 = 0 V  
Leakage Current  
-
<1  
5
µA  
-
-
-135  
-141  
-133  
-138  
P
P
OUT = +29 dBm, VMODE1 = 0 V, V  
OUT = +16 dBm, VMODE1 = +2.4 V  
Noise in Receive Band (2)  
dBm/Hz  
Harmonics  
2fo  
3fo, 4fo  
-
-
-44  
-50  
-35  
-35  
P
OUT < +29 dBm  
dBc  
VSWR  
dBc  
Input Impedance  
-
-
-
-
2:1  
Spurious Output Level  
(all spurious outputs)  
-70  
See Note 3  
Load mismatch stress with no  
permanent degradation or failure  
8:1  
-
-
VSWR Applies over full operating range  
Notes:  
(1) ACLR and Efficiency measured at 836.5 MHz.  
(2) 869 MHz to 894 MHz.  
(3) POUT < +29 dBm, In-band load VSWR < 5:1, Out-of-band load VSWR < 10:1. Applies over all operating conditions.  
Data Sheet - Rev 2.4  
4
08/2010