AWT6146
Table 4: Operating Ranges
PAR AME T E R
Case Temperature (T
C
)
Supply Voltage (V
BATT
)
Regulated Voltage (V
REG
)
Regulated Current (I
REG
)
Regulated Current (I
REG
)
Control Voltage for Maxi mum Power
(V
RAMP_MAX
)
Control Voltage for Mi ni mum Power
(V
RAMP_MIN
)
MIN
-20
3.0
2.7
-
-
-
-
T YP
-
3.5
2.8
6
10
-
0.2
M AX
85
4.8
2.9
-
30
1.6
0.25
U N IT
°C
V
V
mA
µA
V
V
V
BATT
= 4.8 V, V
REG
= 0 V,
V
RAMP
= 0 V,
TX_EN = LOW,
No RF appli ed
TX_EN = HIGH
TX_EN = LOW
C OMME N T S
Power Supply Leakage Current
-
1
10
µA
V
RAMP
Input Capaci tance
V
RAMP
Input Current
Turn ON/OFF Ti me
Duty Cycle
-
-
-
-
3
-
1
-
-
10
2
50
pF
µA
µs
%
V
RAMP
= 0.2 V to V
RAMP_MAX
The device may be operated safely over these conditions; however, parametric performance is
guaranteed only over the conditions defined in the electrical specifications.
Table 5: Digital Inputs
PAR AME T E R
Logic High Voltage (V
IH
)
Logic Low Voltage (V
IL
)
Logic High Current (I
IH
)
Logic Low Current (I
IL
)
MIN
1.2
-
-
-
T YP
-
-
-
-
M AX
V
REG
0.5
30
30
U N IT
V
V
µA
µA
4
ADVANCED PRODUCT INFORMATION - Rev 0.5
11/2003