AIT1042
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
MIN
MAX
+6
UNIT
COMMENTS
SupplyꢀVoltageꢀ(VCC)
RFꢀGainꢀControlꢀVoltageꢀ(VRFAGC
0
0
0
-
V
V
V
)
+6
IFꢀGainꢀControlꢀVoltageꢀ(VIFAGC
RFꢀInputꢀPower
)
+6
+60
dBmV at RFUIN and RFDIN
ElectrostaticꢀDischarge
(HumanꢀBodyꢀModel)
-
250
V
Classꢀ1A
StorageꢀTemperature
-55
+150
°C
Stresses in excess of the absolute ratings may cause permanent damage. Functional operation
is not implied under these conditions. Exposure to absolute ratings for extended periods of
time may adversely affect reliability.
Table 3: Operating Ranges
PARAMETER
MIN
4.75
0
TYP
MAX
5.25
+3
UNIT
SupplyꢀVoltageꢀ(VCC)
RFꢀGainꢀControlꢀVoltageꢀ(VRFAGC
5.00
V
V
V
)
-
-
IFꢀGainꢀControlꢀVoltageꢀ(VIFAGC
)
0
+3
UpconverterꢀRFꢀInputꢀCenter
54
-
1002
MHz
Frequencyꢀ(fRF
)
FirstꢀIFꢀCenterꢀFrequencyꢀ(fIF1
)
1680
35
1690
45
1700
50
MHz
MHz
°C
IFꢀOutputꢀCenterꢀFrequencyꢀ(fIF2
CaseꢀTemperature
)
0
-
+85
The device may be operated safely over these conditions; however, parametric
performance is guaranteed only over the conditions defined in the electrical
specifications.
PRELIMINARY DATA SHEET - Rev 1.0
4
02/2009