AS1310
Datasheet - Electrical Characteristics
Table 3. Electrical Characteristics
Symbol
Parameter
Conditions
Min
Typ
Max
Units
Thermal Protection
Thermal Shutdown
10°C Hysteresis
150
°C
1. The regulator is in startup mode until this voltage is reached. Caution: Do not apply full load current until the device output > 1.75V
2. LBO goes low in startup mode as well as during normal operation if:
- The voltage at the LBI pin is below LBI threshold.
- The voltage at the LBI pin is below 0.1V and VOUT is below 92.5% of its nominal value.
www.austriamicrosystems.com/DC-DC_Step-Up/AS1310
Revision 1.8
5 - 19