AS1310
Datasheet - D e t a i l e d D e s c r i p t i o n
8 Detailed Description
8.1 Hysteretic Boost Converter
Hysteretic boost converters are so called because comparators are the active elements used to determine on-off timing via current and voltage
measurements. There is no continuously operating fixed oscillator, providing an independent timing reference. As a result, a hysteretic or
comparator based converter has a very low quiescent current. In addition, because there is no fixed timing reference, the operating frequency is
determined by external component (inductor and capacitors) and also the loading on the output.
The application circuit shown in
Figure 1
will support many requirements. However, further optimization may be useful, and the following is
offered as a guide to changing the passive components to more closely match the end requirement.
8.1.1
Input Loop Timing
The fixed on-time measurement is something of a safety feature to ensure that the power switch is never permanently on. The fixed on-time is
independent of input voltage changes. As a result, no line regulation exists.
Figure 12. Simplified Boost DCDC Architecture
On time of the power switch (Faraday’s Law) is given by:
hn
ic a
al m
co s
A
nt G
en
ts
til
L1
SW2
The input loop consists of the source dc supply, the input capacitor, the main inductor, and the N-channel power switch. The on timing of the N-
channel switch is determined by a peak current measurement or a maximum on time. In the AS1310, peak current is 400mA (typ) and maximum
on time is 4.2µs (typ). Peak current measurement ensures that the on time varies as the input voltage varies. This imparts line regulation to the
converter.
V
IN
Q
C
IN
SW1
Q
FB
C
OUT
I
PK
GND
0V
LI
PK
-
T
ON
= -----------------------------------------------------------------
sec [volts, amps, ohms, Henry]
V
IN
–
(
I
PK
R
SW1
+
I
PK
R
L1
)
Te
c
Applying Min and Max values and neglecting the resistive voltage drop across L1 and SW1;
T
ON
_
MIN
=
L
MIN
I
PK
_
MIN
V
IN
_
MAX
L
MAX
I
PK
_
MAX
V
IN
_
MIN
(EQ 3)
(EQ 2)
T
ON
_
MAX
=
www.austriamicrosystems.com/DC-DC_Step-Up/AS1310
Revision 1.8
lv
V
OUT
R
LOAD
0V
al
(EQ 1)
8 - 19
Inductor current is monitored by the control loop, ensuring that operation is always dis-continuous.
id
Ripple at the output is an essential operating component. A power cycle is initiated when the output regulated voltage drops below the nominal
value of V
OUT
(0.99 x V
OUT
).