AS1153/55
Data Sheet - Electrical Characteristics
AC Electrical Characteristics
VCC = +3.0 to +3.6V, CLOAD = 10pF, Differential Input Voltage |VID| = 0.2 to 1.0V, Common-Mode Voltage VCM = |VID/2|
to 2.4V -|VID/2|, Input Rise and Fall Time = 1ns (20 to 80%), Input Frequency = 100MHz, TAMB = -40 to +85ºC. Typical
values are at VCC = +3.3V, VCM = 1.2V, |VID| = 0.2V, TAMB = +25ºC (unless otherwise specified). 1, 2
Table 4. AC Electrical Characteristics
Parameter
Symbol
Conditions
Min
Typ
Max Unit
Differential Propagation Delay High-
to-Low
Figure 20 on page 11 and Figure 21 on
page 12
tPHLD
1
1.8
3.1
3.1
ns
ns
Differential Propagation Delay Low-
to-High
Figure 20 on page 11 and Figure 21 on
page 12
tPLHD
tSKD1
1
1.8
Differential Pulse Skew
Figure 20 on page 11 and Figure 21 on
page 12
250
600
600
ps
ps
3
(tPHLD - tPLHD)
Differential Channel-to-Channel
Skew 4
Figure 20 on page 11 and Figure 21 on
page 12
tSKD2
Figure 20 on page 11 and Figure 21 on
page 12
Differential Part-to-Part Skew 5
tSKD3
tSKD4
tTLH
0.8
1.5
1.0
1.0
ns
ns
ns
Figure 20 on page 11 and Figure 21 on
page 12
Differential Part-to-Part Skew 6
Rise Time
Figure 20 on page 11 and Figure 21 on
page 12
0.4
Figure 20 on page 11 and Figure 21 on
page 12
Fall Time
Maximum Operating Frequency 7, 8
Notes:
tTHL
0.4
ns
fMAX
All Channels Switching
130
160
MHz
1. AC parameters are guaranteed by design and characterization.
2. CL includes scope probe and test jig capacitance.
3. tSKD1 is the magnitude difference of differential propagation delays in a channel. tSKD1 = |tPHLD - tPLHD|.
4. tSKD2 is the magnitude difference of the tPLHD or tPHLD of one channel and the tPLHD or tPHLD of any other chan-
nel on the same device.
5. tSKD3 is the magnitude difference of any differential propagation delays between devices operating over rated
conditions at the same VCC and within 5ºC of each other.
6. tSKD4 is the magnitude difference of any differential propagation delays between devices operating over rated
conditions.
7. fMAX generator output conditions:
a. Rise time = fall time = 1ns (0 to 100%)
b. 50% duty cycle
c. VOH = +1.3V
d. VOL = +1.1V
8. Output criteria:
a. Duty cycle = 60% to 40%
b. VOL = 0.4V (max)
c. VOH = 2.7V (min)
d. Load = 10pF
www.austriamicrosystems.com
Revision 1.01
5 - 15