AS1109  
Data Sheet - Detailed Description  
Detailed Error Reports  
The detailed error report can be read out after global error mode has been run. On the falling edge of LD, the detailed  
error report of the selected test is latched into the shift register and can be clocked out with n*8 clock cycles (n is the  
number of AS1109s in a chain) via pin SDO. At the same time new data can be written into the shift register, which will  
load on the next rising edge of pin LD. This data will show at the output drivers, at the falling edge of OEN.  
Detailed Temperature Warning Report  
The detailed temperature warning report can be read out immediately after global error mode has been run. Bit0 of the  
8bit data word represents the temperature flag of the chip.  
Figure 15. Detailed Temperature Warning Report Timing Diagram  
Global Flag Readout  
Detailed Error Report Readout  
OEN  
tH(L)  
tGSW(ERROR)  
t(SU)ERROR  
LD  
tP4  
CLK  
Don’t  
Care  
DBit7  
DBit6 DBit5 DBit4 DBit3 DBit2  
New Data Input  
DBit1 DBit0  
SDI  
Don’t  
Care  
TFLAG  
TBit0  
SDO  
Undefined  
Temperature Error Report Output  
tP4  
tP1  
For detailed timing information see Timing Diagrams on page 9.  
Detailed Temperature Warning Report Example  
Consider a case where five AS1109s are cascaded in one chain. The detailed error report lists the temperatures for  
each device in the chain:  
IC1:[70°] IC2:[85°] IC3:[66°] IC4:[160°] IC5:[76°]  
In this case, IC4 is overheated and will generate a global error, and therefore 5*8 clock cycles are needed to write out  
the detailed temperature warning report, and optionally read in new data. The detailed temperature warning report  
would look like this:  
XXXXXXX1 XXXXXXX1 XXXXXXX1 XXXXXXX0 XXXXXXX1  
The 0 in the detailed temperature warning report indicates that IC4 is the device with the over-temperature condition.  
Note: In an actual report there are no spaces in the output.  
www.austriamicrosystems.com  
Revision 1.18  
13 - 26