AS1101/AS1102/AS1103/AS1104
Data Sheet
- A b s o l u t e M a x i m u m R a t i n g s
5 Absolute Maximum Ratings
Stresses beyond those listed in
may cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond those listed in
is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reli-
ability.
Table 2. Absolute Maximum Ratings
Parameter
V
I1
, V
I2
, V
I3
, V
I4
, CTRL and ON Voltage to GND
Power Dissipated by Device at T
AMB
= 85°C
I1, I2, I3, I4 Steady State Current
Package Body Temperature
Junction Temperature
Storage Temperature
Electrostatic Discharge Protection (ESD) Level
†
†
Min
-0.3
Max
5
200
250
100
260
150
Unit
V
mW
mW
mA
ºC
ºC
ºC
kV
Comment
SC70-6
MSOP-8
-65
2
150
Human Body Model;
Norm: MIL-STD883E 3015
methods.
The reflow peak soldering temperature (body temperature) is specified according to
IPC/JEDEC J-STD-020C “Mois-
ture/Reflow Sensitivity Classification for Non-Hermetic Solid State Surface Mount Devices”.
Operating Conditions
Table 3. Recommended Operating Conditions
Parameter
LED Cathode Voltage
Enable Voltage ON Mode
Enable Voltage OFF Mode
Ambient Temperature
†
†
†
Min
0.15
2.2
0
-40
Typ
0.6
3.0
0.2
25
Max
3.6
3.6
0.5
85
Unit
V
V
V
ºC
Comments
Not applicable to AS1103.
www.austriamicrosystems.com
Revision 1.5
3 - 13