Recommended DC Operating Conditions
(TA = 0°C to + 70°C or -40°C to +85°C)
Symbol
VCC
GND
VIH
Parameter
Supply Voltage
Min.
2.7
Typ.
Max.
3.6
0
Unit
V
3.0
0
Ground
0
V
Input High Voltage
Input Low Voltage
VCC * 0.7
-0.3
-
VCC + 0.3
+0.3
V
V
VIL
0
Absolute Maximum Ratings*
*Comments
VCC to GND . . . . . . . . . . . . . . . . . . . . . -0.5V to +3.6V
IN, IN/OUT Volt to GND . . . . . . . . . -0.5V to VCC + 0.5V
Operating Temperature, Topr . . . . . . . . . . 0°C to +70°C
Storage Temperature, Tstg . . . . . . . . . -55°C to +125°C
Power Dissipation, PT . . . . . . . . . . . . . . . . . . . . . 0.7W
Soldering Temp. & Time . . . . . . . . . . . . . 260°C, 10 sec
Stresses above those listed under "Absolute Maximum
Ratings" may cause permanent damage to the device.
These are stress ratings only. Functional operation of this
device at these or any other conditions above those
indicated in the operational sections of this specification
is not implied and exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
DC Electrical Characteristics (TA = 0°C to + 70°C or -40ºC to +85ºC, VCC = 2.7V to 3.6V, GND = 0V)
A62L256-55LL/55LLU
A62L256-70LL/70LLU
Symbol
Parameter
Unit
Conditions
Min.
Typ.
Max.
Min.
Typ.
Max.
Input Leakage
Current
-
-
1
-
-
1
VIN = GND to VCC
½ILI½
mA
CE = VIH or WE = VIL
VI/O = GND to VCC
Output Leakage
Current
-
-
-
1
-
-
-
1
½ILO½
ICC1
mA
Dynamic
Operating Current
Min. Cycle, Duty = 100%
*18
25
**12
20
mA
CE = VIL, II/O = 0mA
CE = VIL, VIH = VCC
VIL = 0V, f = 1 MHz
II/O = 0 mA
Dynamic
Operating Current
ICC2
-
1
3
-
1
3
mA
Typical values are measured at VCC = 3.0V, TA = 25°C and not 100% tested.
* Testing condition : TA = 25°C, VCC = 3.0V, Cycle Time = 55 ns
** Testing condition : TA = 25°C, VCC = 3.0V, Cycle Time = 70 ns
PRELIMINARY
(November, 2001, Version 1.4)
4
AMIC Technology, Inc.