 浏览型号AMIS-30623-AGA的Datasheet PDF文件第41页浏览型号AMIS-30623-AGA的Datasheet PDF文件第42页浏览型号AMIS-30623-AGA的Datasheet PDF文件第43页浏览型号AMIS-30623-AGA的Datasheet PDF文件第44页浏览型号AMIS-30623-AGA的Datasheet PDF文件第46页浏览型号AMIS-30623-AGA的Datasheet PDF文件第47页浏览型号AMIS-30623-AGA的Datasheet PDF文件第48页浏览型号AMIS-30623-AGA的Datasheet PDF文件第49页  
AMIS-30623 LIN Microstepping Motordriver  
Data Sheet  
16.6.2. Reading Frames  
A reading frame uses an in-frame response mechanism. That is: the master initiates the frame (synchronization field + identifier field),  
and one slave sends back the data field together with the check field. Hence, two types of identifiers can be used for a reading frame:  
Direct ID, which points at a particular slave node, indicating at the same time which kind of information is awaited from this slave  
node, thus triggering a specific command. This ID provides the fastest access to a read command but is forbidden for any other  
action.  
Indirect ID, which only specifies a reading command, the physical address of the slave node that must answer having been passed in  
a previous writing frame, called a preparing frame. Indirect ID gives more flexibility than a direct one, but provides a slower access to  
a read command.  
Notes  
(1) a reading frame with indirect ID must always be consecutive to a preparing frame. It will otherwise not be taken into account.  
(2) a reading frame will always return the physical address of the answering slave node in order to ensure robustness in the communication.  
The reading frames used with the AMIS-30623 are the following:  
Type #5: 2, 4 or 8 Data bytes reading frame with a direct identifier dynamically assigned to a particular slave node together  
with an application command. A preparing frame is not needed.  
Type #6: 8 Data bytes reading frame with 0x3D identifier. This is intrinsically an indirect type, needing therefore a preparation  
frame. It has the advantage to use a reserved identifier.  
16.6.3. Preparing Frames  
A preparing frame is a writing frame that warns a particular slave node that it will have to answer in the next frame (hence a reading  
frame). A preparing frame is needed when a reading frame does not use a dynamically assigned direct ID. Preparing and reading  
frames must be consecutive. A preparing frame will contain the physical address of the LIN slave node that must answer in the reading  
frame, and will also contain a command indicating which kind of information is awaited from the slave.  
The preparing frames used with the AMIS-30623 can be of type #7 or type #8 described below.  
Type #7: two data bytes writing frame with dynamically assigned identifier.  
Preparing Frame  
Byte  
Content  
Structure  
Bit 7  
Bit 6  
*
Bit 5  
0
Bit 4  
ID4  
Bit 3  
ID3  
CMD[6:0]  
AD[6:0]  
Bit 2  
ID2  
Bit 1  
ID1  
Bit 0  
ID0  
*
1
1
0
1
Identifier  
Data 1  
2
Data 2  
Where:  
(*)  
According to parity computation  
Type #8: eight data bytes writing frame with 0x3C identifier.  
SetDualPositioning Writing Frame  
Structure  
Byte  
Content  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
0
0
1
1
1
1
0
0
0
1
2
3
4
5
6
7
8
Identifier  
Data 1  
Data 2  
Data 3  
Data 4  
Data 5  
Data 6  
Data 7  
Data 8  
AppCMD = 0x80  
CMD[6:0]  
1
1
AD[6:0]  
Data4[7:0]  
Data5[7:0]  
Data6[7:0]  
Data7[7:0]  
Data8[7:0]  
Where:  
AppCMD:  
CMD[6:0]:  
AD[6:0]:  
If = ‘0x80’ this indicates that Data 2 contains an application command  
Application Command “byte”  
Slave node physical address  
Datan[7:0]: Data transmitted  
AMI Semiconductor – June 2006, Rev 3.0  