Revision 5.01 – November 30, 2005
S5335 – PCI Bus Controller, 3.3V
Data Sheet
Built-In Self-test Register (BIST)
The Built-In Self-Test (BIST) register permits the
implementation of custom, user-specific diagnostics.
This register has four fields as depicted in Figure 16.
Bit 7, when set signifies that this device supports a
built-in self test. When bit 7 is set, writing a 1 to bit 6
will commence the self test. In actuality, writing a 1 to
bit 6 produces an interrupt to the Add-On interface. Bit
6 will remain set until cleared by a write operation to
this register from the Add-On bus interface. When bit 6
is reset it is interpreted as completion of the self-test
and an error is indicated by a non-zero value for the
completion code (bits 3:0).
Built-in Self-Test
Register Name:
Address Offset:
Power-up value:
Boot-load:
0Fh
00h
External nvRAM/EPROM offset 04Fh
D7, D5-0 Read Only, D6 as PCI bus
write only
Attribute:
8 bits
Size:
Figure 16. Built-In Self Test Register
7
6
5
4
0
3
2
1
0
Bit
X
0
0
X
X
X
X
Value
User defined
Completion Code (RO)
Reserved (RO)
Start BIST (WO)
BIST Capable (RO)
Table 36. Built-In Self-Test Register
Bit
Description
7
BIST Capable. This bit indicates that the Add-On device supports a built-in self-test when a one is returned. A zero
should be returned if this self test feature is not desired. This field is read only from the PCI interface.
6
Start BIST. Writing a 1 to this bit indicates that the self-test should commence. This bit can only be written when bit 7 is
a 1. When bit 6 becomes set, an interrupt is issued to the Add-On interface. Other than through the reset pin, Bit 6 can
only be cleared by a write to this element from the Add-On bus interface as outlined in Section 6.5. The PCI bus spec-
ification requires that this bit be cleared within 2 seconds after being set, or the device will be failed.
5:4 Reserved. These bits are reserved. This field will always return zeros.
3:0 Completion Code. This field provides a method for detailing a device-specific error. It is considered valid when the Start
BIST field (bit 6) changes from 1 to 0. An all-zero value for the completion code indicates successful completion.
AMCC Confidential and Proprietary