FLEX 6000 Programmable Logic Device Family Data Sheet
Table 26. Interconnect Timing Microparameters for EPF6010A & EPF6016A Devices
Parameter
Speed Grade
-2
Unit
-1
-3
Min
Max
Min
Max
Min
Max
tLOCAL
0.7
2.9
1.2
5.4
4.3
2.6
0.7
1.3
0.7
3.2
1.3
5.7
5.0
3.0
0.8
1.4
1.0
3.2
1.4
6.4
6.1
3.7
0.9
1.8
ns
ns
ns
ns
ns
ns
ns
ns
tROW
tCOL
tDIN_D
tDIN_C
tLEGLOBAL
tLABCARRY
tLABCASC
Table 27. External Reference Timing Parameters for EPF6010A & EPF6016A Devices
Parameter
Device
Speed Grade
-2
Unit
-1
-3
Min
Max
Min
Max
Min
Max
t1
EPF6010A
EPF6016A
37.6
38.0
43.6
44.0
53.7
54.1
ns
ns
Table 28. External Timing Parameters for EPF6010A & EPF6016A Devices
Parameter
Speed Grade
-2
Unit
-1
-3
Min
Max
Min
Max
Min
Max
tINSU
2.1 (1)
0.2 (2)
2.0
2.4 (1)
0.3 (2)
2.0
3.3 (1)
0.1 (2)
2.0
ns
ns
ns
tINH
tOUTCO
7.1
8.2
10.1
Notes:
(1) Setup times are longer when the Increase Input Delay option is turned on. The setup time values are shown with the
Increase Input Delay option turned off.
(2) Hold time is zero when the Increase Input Delay option is turned on.
42
Altera Corporation