6–8
Chapter 6: I/O Features in the Cyclone III Device Family
OCT Support
On-Chip Series Termination with Calibration
The Cyclone III device family supports on-chip series termination with calibration in
all banks. The on-chip series termination calibration circuit compares the total
impedance of the output buffer to the external 25- ±1% or 50- ±1% resistors
connected to the
RUP
and
RDN
pins, and dynamically adjusts the output buffer
impedance until they match (as shown in
The R
S
shown in
is the intrinsic impedance of the transistors that make up
the output buffer.
Figure 6–2. Cyclone III Device Family On-Chip Series Termination with Calibration
Cyclone III Device Family
Driver Series Termination
V
CCIO
Receiving
Device
R
S
Z
O
R
S
GND
OCT with calibration is achieved using the OCT calibration block circuitry. There is
one OCT calibration block in banks 2, 4, 5, and 7. Each calibration block supports each
side of the I/O banks. Because there are two I/O banks sharing the same calibration
block, both banks must have the same V
CCIO
if both banks enable OCT calibration. If
two related banks have different V
CCIO
s, only the bank in which the calibration block
resides can enable OCT calibration.
Cyclone III Device Handbook
Volume 1
July 2012 Altera Corporation