 浏览型号EP2C35F672C8N的Datasheet PDF文件第308页浏览型号EP2C35F672C8N的Datasheet PDF文件第309页浏览型号EP2C35F672C8N的Datasheet PDF文件第310页浏览型号EP2C35F672C8N的Datasheet PDF文件第311页浏览型号EP2C35F672C8N的Datasheet PDF文件第313页浏览型号EP2C35F672C8N的Datasheet PDF文件第314页浏览型号EP2C35F672C8N的Datasheet PDF文件第315页浏览型号EP2C35F672C8N的Datasheet PDF文件第316页  
Pad Placement and DC Guidelines  
If the bidirectional pads are all controlled by the same output enable (OE)  
and there are no other outputs or voltage referenced inputs in the bank,  
then there is no case where there is a voltage referenced input is active at  
the same time as an output. Therefore, the output limitation does not  
apply. However, since the bidirectional pads are linked to the same OE,  
all the bidirectional pads act as inputs at the same time. Therefore, the  
input limitation of 30 input pads (15 on each side of the VREF pad) for  
FineLine BGA packages and 20 input pads (10 on each side of the VREF  
pad) for QFP packages applies.  
If the bidirectional pads are all controlled by different OEs, and there are  
no other outputs or voltage referenced inputs in the bank, then there may  
be a case where one group of bidirectional pads is acting as inputs while  
another group is acting as outputs. In such cases, apply the formulas  
shown in Table 10–8.  
Table 10–8. Input-Only Bidirectional Pad Limitation Formulas  
Package Type  
Formula  
FineLine BGA  
(Total number of bidirectional pads) – (Total number of pads  
from the smallest group of pads controlled by an OE) 9  
(per VCCIOand ground pair)  
QFP  
(Total number of bidirectional pads) – (Total number of pads  
from the smallest group of pads controlled by an OE) 5  
(per VCCIOand ground pair).  
Consider a FineLine BGA package with four bidirectional pads controlled  
by the first OE, four bidirectional pads controlled by the second OE, and  
two bidirectional pads controlled by the third OE. If the first and second  
OEs are active and the third OE is inactive, there are 10 bidirectional pads,  
but it is safely allowable because there would be 8 or fewer outputs per  
VCCIO/GNDpair.  
When at least one additional voltage referenced input and no other  
outputs exist in the same VREF bank, the bidirectional pad limitation  
applies in addition to the input and output limitations. See the following  
equations:  
Total number of bidirectional pads + total number of input pads 30  
(15 on each side of your VREF pad) for Fineline BGA packages  
Total number of bidirectional pads + total number of input pads 20  
(10 on each side of your VREF pad) for QFP packages  