EP220 & EP224 Classic EPLDs
AC Operating Conditions: -7 & -10 Speed Grades
Combinatorial Mode
Note (1)
EP220-7
EP224-7
EP220-10
EP224-10
Symbol
Parameter
Min Max Min Max Units
tPD1
Input or I/O to non-registered output, inversion on, Note (2)
Input or I/O to non-registered output, inversion off, Note (2)
Input or I/O to output enable, Note (3)
7.5
8.5
9
10
10
ns
ns
ns
ns
ps
ps
tPD2
tPZX
tPXZ
tOSR
tOSC
10
Input or I/O to output disable, Note (3)
9
10
Register mode output-to-output skew
300
400
300
400
Combinatorial mode output-to-output skew
EP220-7
EP224-7
EP220-10
EP224-10
Synchronous Clock Mode
Symbol
Parameter
Min Max Min Max Units
fMAX
fCNT1
fCNT2
tSU1
tH
Maximum frequency (pipelined), no feedback, Note (2)
Maximum counter frequency, external feedback, Note (2)
Maximum counter frequency, internal feedback, Note (2)
Input or I/O setup time to global clock
Input or I/O hold time from global clock
Global clock to output delay, Note (2)
Global clock to output delay through combinatorial macrocell
Minimum global clock period, Note (2)
Clock low time
100
74
100
7
62.5
58.8
60.6
10
MHz
MHz
MHz
ns
0
0
ns
tCO1
tCO2
tCNT
tCL
6.5
11
10
7
ns
13
ns
16.5
ns
4
4
7
7
ns
tCH
Clock high time
ns
tCP
Clock period
10
16
ns
Notes to tables:
(1) Operating conditions: VCC = 5 V ± 5%, TA = 0° C to 70° C for commercial use.
(2) Measured with three I/O outputs switching.
(3) The tPZX and tPXZ parameters are measured at ± 0.5 V from steady-state voltage that is driven by the specified
output load. The tPXZ parameter is measured with CL = 5 pF and with all eight outputs switching.
14
Altera Corporation