6. DC & Switching
Characteristics
SGX51006-1.2
Operating
Conditions
Stratix
®
GX devices are offered in both commercial and industrial grades.
However, industrial-grade devices may have limited speed-grade
availability.
through
provide information on absolute maximum
ratings, recommended operating conditions, DC operating conditions,
and transceiver block absolute maximum ratings. Notes for
through
immediately follow
notes for
immediately follow that table, and notes for
through
immediately follow
Table 6–1. Stratix GX Device Absolute Maximum Ratings
Symbol
V
CCINT
V
CCIO
V
I
I
OUT
T
STG
T
AMB
T
J
DC input voltage
DC output current, per pin
Storage temperature
Ambient temperature
Junction temperature
No bias
Under bias
Minimum
–0.5
–0.5
–0.5
–25
–65
–65
Parameter
Supply voltage
Conditions
With respect to ground
Maximum
2.4
4.6
4.6
25
150
135
135
Unit
V
V
V
mA
°
C
°
C
°
C
BGA packages under bias
Table 6–2. Stratix GX Device Recommended Operating Conditions (Part 1 of 2)
Symbol
V
CCINT
V
CCIO
Maximum
1.575
3.60 (3.465)
2.625
1.89
1.6
4.1
Parameter
Supply voltage for internal logic
and input buffers
Conditions
Minimum
1.425
3.00 (3.135)
2.375
1.71
1.4
–0.5
Unit
V
V
V
V
V
V
Supply voltage for output buffers,
3.3-V operation
Supply voltage for output buffers,
2.5-V operation
Supply voltage for output buffers,
1.8-V operation
Supply voltage for output buffers,
1.5-V operation
V
I
Input voltage
Altera Corporation
June 2006
6–1