Operating Conditions
Table 4–2. Stratix Device Recommended Operating Conditions (Part 2 of 2)
Symbol
Parameter
Conditions
Minimum
Maximum
Unit
VCCIO
Supply voltage for output
buffers, 3.3-V operation
(4), (5)
3.00 (3.135)
3.60 (3.465)
V
Supply voltage for output
buffers, 2.5-V operation
(4)
2.375
1.71
1.4
2.625
1.89
1.6
V
V
V
Supply voltage for output
buffers, 1.8-V operation
(4)
Supply voltage for output
buffers, 1.5-V operation
(4)
VI
Input voltage
(3), (6)
–0.5
0
4.0
VCCIO
85
V
V
VO
TJ
Output voltage
Operating junction
temperature
For commercial use
For industrial use
0
°C
°C
–40
100
Table 4–3. Stratix Device DC Operating Conditions Note (7) (Part 1 of 2)
Symbol
Parameter
Conditions
Minimum
Typical
Maximum
Unit
II
Input pin leakage
current
VI = VCCIOmax to 0 V (8)
–10
10
μA
IOZ
Tri-stated I/O pin
leakage current
VO = VCCIOmax to 0 V (8)
–10
10
μA
ICC0
VCC supply current VI = ground, no load, no
mA
mA
mA
mA
mA
mA
mA
mA
(standby) (All
toggling inputs
memory blocks in
power-down mode)
EP1S10. VI = ground, no
load, no toggling inputs
37
65
EP1S20. VI = ground, no
load, no toggling inputs
EP1S25. VI = ground, no
load, no toggling inputs
90
EP1S30. VI = ground, no
load, no toggling inputs
114
145
200
277
EP1S40. VI = ground, no
load, no toggling inputs
EP1S60. VI = ground, no
load, no toggling inputs
EP1S80. VI = ground, no
load, no toggling inputs
4–2
Altera Corporation
July 2005
Stratix Device Handbook, Volume 1