 浏览型号EP1S20F672C7N的Datasheet PDF文件第194页浏览型号EP1S20F672C7N的Datasheet PDF文件第195页浏览型号EP1S20F672C7N的Datasheet PDF文件第196页浏览型号EP1S20F672C7N的Datasheet PDF文件第197页浏览型号EP1S20F672C7N的Datasheet PDF文件第199页浏览型号EP1S20F672C7N的Datasheet PDF文件第200页浏览型号EP1S20F672C7N的Datasheet PDF文件第201页浏览型号EP1S20F672C7N的Datasheet PDF文件第202页  
Power Consumption  
device. Decoupling capacitors were not used in this measurement. To  
factor in the current for decoupling capacitors, sum up the current for  
each capacitor using the following equation:  
I = C (dV/dt)  
If the regulator or power supply minimum output current is more than  
the Stratix device requires, then the device may consume more current  
than the maximum current listed in Table 4–34. However, the device does  
not require any more current to successfully power up than what is listed  
in Table 4–34.  
Table 4–34. Stratix Power-Up Current (ICCINT) Requirements Note (1)  
Power-Up Current Requirement  
Device  
Unit  
Typical  
Maximum  
EP1S10  
EP1S20  
EP1S25  
EP1S30  
EP1S40  
EP1S60  
EP1S80  
250  
400  
700  
mA  
mA  
mA  
mA  
mA  
mA  
mA  
1,200  
1,500  
1,900  
2,300  
2,600  
3,000  
500  
550  
650  
800  
1,000  
Note to Table 4–34:  
(1) The maximum test conditions are for 0° C and typical test conditions are for  
40° C.  
The exact amount of current consumed varies according to the process,  
temperature, and power ramp rate. Stratix devices typically require less  
current during power up than shown in Table 4–34. The user-mode  
current during device operation is generally higher than the power-up  
current.  
The duration of the ICCINT power-up requirement depends on the VCCINT  
voltage supply rise time. The power-up current consumption drops when  
the VCCINT supply reaches approximately 0.75 V.  