Chapter 4: DC and Switching Characteristics  
4–3  
Operating Conditions  
Table 4–3. Arria GX Device Recommended Operating Conditions (Part 2 of 2)  
(Note 1) (Part 2 of 2)  
Symbol  
Parameter  
Conditions  
For commercial use  
Minimum  
Maximum  
Units  
0
85  
C
C
TJ  
Operating junction temperature  
For industrial use  
–40  
100  
Notes to Table 4–3:  
(1) Supply voltage specifications apply to voltage readings taken at the device pins, not at the power supply.  
(2) During transitions, the inputs may overshoot to the voltage shown in Table 4–2 based upon the input duty cycle. The DC case is equivalent to  
100% duty cycle. During transitions, the inputs may undershoot to –2.0 V for input currents less than 100 mA and periods shorter than 20 ns.  
(3) Maximum VCC rise time is 100 ms, and VCC must rise monotonically from ground to VCC  
.
(4) VCCPD must ramp-up from 0 V to 3.3 V within 100 s to 100 ms. If VCCPD is not ramped up within this specified time, the Arria GX device will  
not configure successfully. If the system does not allow for a VCCPD ramp-up time of 100 ms or less, hold nCONFIGlow until all power supplies  
are reliable.  
(5) All pins, including dedicated inputs, clock, I/O, and JTAG pins, can be driven before VCCINT, VCCPD, and VCCIO are powered.  
(6) VCCIO maximum and minimum conditions for PCI and PCI-X are shown in parentheses.  
Transceiver Block Characteristics  
Table 4–4 through Table 4–6 on page 4–4 contain transceiver block specifications.  
Table 4–4. Arria GX Transceiver Block Absolute Maximum Ratings  
(Note 1)  
Symbol  
VCCA  
Parameter  
Conditions  
Minimum  
–0.5  
Maximum  
4.6  
Units  
Transceiver block supply voltage  
Transceiver block supply voltage  
Transceiver block supply voltage  
Transceiver block supply voltage  
Transceiver block supply voltage  
Transceiver block supply voltage  
Commercial and industrial  
Commercial and industrial  
Commercial and industrial  
Commercial and industrial  
Commercial and industrial  
Commercial and industrial  
V
V
V
V
V
V
VCCP  
–0.5  
1.8  
VCCR  
–0.5  
1.8  
VCCT_B  
VCCL_B  
VCCH_B  
–0.5  
1.8  
–0.5  
1.8  
–0.5  
2.4  
Note to Table 4–4:  
(1) The device can tolerate prolonged operation at this absolute maximum, as long as the maximum specification is not violated.  
Table 4–5. Arria GX Transceiver Block Operating Conditions  
Symbol  
VCCA  
Parameter  
Conditions  
Minimum Typical Maximum Units  
Transceiver block supply voltage  
Transceiver block supply voltage  
Transceiver block supply voltage  
Transceiver block supply voltage  
Transceiver block supply voltage  
Commercial and industrial  
Commercial and industrial  
Commercial and industrial  
Commercial and industrial  
Commercial and industrial  
3.135  
1.15  
3.3  
1.2  
1.2  
1.2  
1.2  
1.2  
1.5  
2K  
3.465  
1.25  
V
V
V
V
V
V
V
VCCP  
VCCR  
1.15  
1.25  
VCCT_B  
VCCL_B  
1.15  
1.25  
1.15  
1.25  
1.15  
1.25  
VCCH_B  
Transceiver block supply voltage  
Commercial and industrial  
1.425  
2K - 1%  
1.575  
2K +1%  
RREFB (1)  
Reference resistor  
Commercial and industrial  
Note to Table 4–5:  
(1) The DC signal on this pin must be as clean as possible. Ensure that no noise is coupled to this pin.  
© December 2009 Altera Corporation  
Arria GX Device Handbook, Volume 1