EP220 & EP224 Classic EPLDs  
AC Operating Conditions: -7A, -10A, & -12 Speed Grades  
Combinatorial Mode  
Note (1)  
EP220-7A EP220-10A EP220-12 Non-Turbo  
EP224-7A EP224-10A EP224-12 Adder  
Symbol  
Parameter  
Min Max Min Max Min Max Note (2) Units  
tPD1  
tPD2  
tPZX  
tPXZ  
tOSR  
tOSC  
Input to non-registered output, Note (3)  
I/O to non-registered output, Note (3)  
Input or I/O to output enable, Note (4)  
Input or I/O to output disable, Note (4)  
Register-mode output to output skew  
Combinatorial-mode output to output skew  
7.5  
7.5  
9
10  
10  
12  
10  
-
12  
12  
12  
12  
-
20  
20  
20  
20  
-
ns  
ns  
ns  
ns  
ps  
ps  
9
300  
400  
-
-
-
EP220-7A EP220-10A EP220-12 Non-Turbo  
EP224-7A EP224-10A EP224-12 Adder  
Synchronous Clock Mode  
Symbol  
Parameter  
Min Max Min Max Min Max Note (2) Units  
fMAX  
fCNT1  
fCNT2  
Maximum frequency (pipelined), no feedback,  
Note (3)  
115  
100  
115  
111  
90.9  
-
-
-
MHz  
MHz  
MHz  
Maximum counter frequency, external feedback,  
Note (3)  
80  
66  
Maximum counter frequency, internal feedback,  
Note (3)  
100  
83.3  
tSU1  
tH  
tCO1  
tCO2  
Input or I/O setup time to global clock  
Input or I/O hold time from global clock  
Global clock to output delay, Note (3)  
4.5  
0
7
0
9
0
20  
0
ns  
ns  
ns  
ns  
5.5  
10  
5.5  
13  
6
0
Global clock to output delay through combinatorial  
macrocell  
15  
20  
tCNT  
tCL  
tCH  
tCP  
Minimum global clock period, Note (3)  
Clock low time  
10  
10  
12  
20  
0
ns  
ns  
ns  
ns  
4
4
4
4
9
5
5
Clock high time  
0
Clock period  
10  
11  
0
Notes to tables:  
(1) Operating conditions: VCC = 5 V ± 5%, TA = 0° C to 70° C for commercial use.  
CC = 5 V ± 5%, TA = –40° C to 85° C for industrial use.  
V
(2) If the device enters standby mode and remains inactive for approximately 75 ns, increase the time by the amount  
shown. For EP220-10A, EP220-12, and EP224-10A, EP224-12 devices only.  
(3) Measured with all outputs switching.  
(4) The tPZX and tPXZ parameters are measured at ± 0.5 V from steady-state voltage that is driven by the specified  
output load. The tPXZ parameter is measured with CL = 5 pF and with all eight outputs switching.  
Altera Corporation  