EP220 & EP224 Classic EPLDs
AC Operating Conditions: -7A, -10A, & -12 Speed Grades
Combinatorial Mode
Note (1)
EP220-7A EP220-10A EP220-12 Non-Turbo
EP224-7A EP224-10A EP224-12 Adder
Symbol
Parameter
Min Max Min Max Min Max Note (2) Units
tPD1
tPD2
tPZX
tPXZ
tOSR
tOSC
Input to non-registered output, Note (3)
I/O to non-registered output, Note (3)
Input or I/O to output enable, Note (4)
Input or I/O to output disable, Note (4)
Register-mode output to output skew
Combinatorial-mode output to output skew
7.5
7.5
9
10
10
12
10
-
12
12
12
12
-
20
20
20
20
-
ns
ns
ns
ns
ps
ps
9
300
400
-
-
-
EP220-7A EP220-10A EP220-12 Non-Turbo
EP224-7A EP224-10A EP224-12 Adder
Synchronous Clock Mode
Symbol
Parameter
Min Max Min Max Min Max Note (2) Units
fMAX
fCNT1
fCNT2
Maximum frequency (pipelined), no feedback,
Note (3)
115
100
115
111
90.9
-
-
-
MHz
MHz
MHz
Maximum counter frequency, external feedback,
Note (3)
80
66
Maximum counter frequency, internal feedback,
Note (3)
100
83.3
tSU1
tH
tCO1
tCO2
Input or I/O setup time to global clock
Input or I/O hold time from global clock
Global clock to output delay, Note (3)
4.5
0
7
0
9
0
20
0
ns
ns
ns
ns
5.5
10
5.5
13
6
0
Global clock to output delay through combinatorial
macrocell
15
20
tCNT
tCL
tCH
tCP
Minimum global clock period, Note (3)
Clock low time
10
10
12
20
0
ns
ns
ns
ns
4
4
4
4
9
5
5
Clock high time
0
Clock period
10
11
0
Notes to tables:
(1) Operating conditions: VCC = 5 V ± 5%, TA = 0° C to 70° C for commercial use.
CC = 5 V ± 5%, TA = –40° C to 85° C for industrial use.
V
(2) If the device enters standby mode and remains inactive for approximately 75 ns, increase the time by the amount
shown. For EP220-10A, EP220-12, and EP224-10A, EP224-12 devices only.
(3) Measured with all outputs switching.
(4) The tPZX and tPXZ parameters are measured at ± 0.5 V from steady-state voltage that is driven by the specified
output load. The tPXZ parameter is measured with CL = 5 pF and with all eight outputs switching.
Altera Corporation
13