Chapter 8: External Memory Interfaces in the Cyclone III Device Family  
8–11  
Cyclone III Device Family Memory Interfaces Features  
Cyclone III Device Family Memory Interfaces Features  
This section describes Cyclone III device family memory interfaces, including DDR  
input registers, DDR output registers, OCT, and phase-lock loops (PLLs).  
DDR Input Registers  
The DDR input registers are implemented with three internal logic element (LE)  
registers for every DQpin. These LE registers are located in the logic array block (LAB)  
adjacent to the DDR input pin.  
Figure 8–4 shows Cyclone III device family DDR input registers.  
Figure 8–4. Cyclone III Device Family DDR Input Registers  
DDR Input Registers in Cyclone III Device Family  
DQ  
LE  
Register  
dataout_h  
Input Register AI  
neg_reg_out  
dataout_l  
LE  
Register  
LE  
Register  
Register CI  
Input Register BI  
Capture Clock  
PLL  
The DDR data is first fed to two registers, input register AI and input register BI.  
Input register AI captures the DDR data present during the rising edge of the clock  
Input register BI captures the DDR data present during the falling edge of the clock  
Register CI aligns the data before it is synchronized with the system clock  
The data from the DDR input register is fed to two registers, sync_reg_hand  
sync_reg_l, then the data is typically transferred to a FIFO block to synchronize the  
two data streams to the rising edge of the system clock. Because the read-capture  
clock is generated by the PLL, the read-data strobe signal (DQSor CQ) is not used  
during read operation in Cyclone III device family; hence, postamble is not a concern  
in this case.  
July 2012 Altera Corporation  
Cyclone III Device Handbook  
Volume 1