Operating Conditions  
Table 5–23. 1.5-V HSTL Class I Specifications  
Symbol  
VCCIO  
VREF  
Parameter  
Conditions  
Minimum  
1.425  
Typical  
1.500  
0.750  
0.750  
Maximum Unit  
Output supply voltage  
Input reference voltage  
Termination voltage  
1.575  
0.788  
0.788  
V
V
V
V
V
V
V
V
V
0.713  
VTT  
0.713  
V
V
V
V
IH (DC)  
IL (DC)  
IH (AC)  
IL (AC)  
DC high-level input voltage  
DC low-level input voltage  
AC high-level input voltage  
AC low-level input voltage  
High-level output voltage  
Low-level output voltage  
VREF + 0.1  
–0.3  
VREF – 0.1  
VREF – 0.2  
0.4  
VREF + 0.2  
VOH  
VOL  
IOH = 8 mA (1)  
IOH = –8 mA (1)  
VCCIO – 0.4  
Note to Table 5–23:  
(1) This specification is supported across all the programmable drive settings available for this I/O standard as shown  
in the Stratix II Architecture chapter in volume 1 of the Stratix II Device Handbook.  
Table 5–24. 1.5-V HSTL Class II Specifications  
Symbol  
VCCIO  
VREF  
Parameter  
Conditions  
Minimum  
1.425  
Typical  
1.500  
0.750  
0.750  
Maximum Unit  
Output supply voltage  
Input reference voltage  
Termination voltage  
1.575  
0.788  
0.788  
V
V
V
V
V
V
V
V
V
0.713  
VTT  
0.713  
V
V
V
V
IH (DC)  
IL (DC)  
IH (AC)  
IL (AC)  
DC high-level input voltage  
DC low-level input voltage  
AC high-level input voltage  
AC low-level input voltage  
High-level output voltage  
Low-level output voltage  
VREF + 0.1  
–0.3  
VREF – 0.1  
VREF – 0.2  
0.4  
VREF + 0.2  
VOH  
VOL  
IOH = 16 mA (1)  
IOH = –16 mA (1)  
VCCIO – 0.4  
Note to Table 5–24:  
(1) This specification is supported across all the programmable drive settings available for this I/O standard as shown  
in the Stratix II Architecture chapter in volume 1 of the Stratix II Device Handbook.  