欢迎访问ic37.com |
会员登录 免费注册
发布采购

CDPCLK6 参数 Datasheet PDF下载

CDPCLK6图片预览
型号: CDPCLK6
PDF下载: 下载PDF文件 查看货源
内容描述: 的Cyclone III器件手册 [Cyclone III Device Handbook]
分类和应用:
文件页数/大小: 274 页 / 7302 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号CDPCLK6的Datasheet PDF文件第219页浏览型号CDPCLK6的Datasheet PDF文件第220页浏览型号CDPCLK6的Datasheet PDF文件第221页浏览型号CDPCLK6的Datasheet PDF文件第222页浏览型号CDPCLK6的Datasheet PDF文件第224页浏览型号CDPCLK6的Datasheet PDF文件第225页浏览型号CDPCLK6的Datasheet PDF文件第226页浏览型号CDPCLK6的Datasheet PDF文件第227页  
Chapter 9: Configuration, Design Security, and Remote System Upgrades in the Cyclone III Device Family  
9–65  
Configuration Features  
Table 9–21 lists the Cyclone III device family pin configuration.  
Table 9–21. Cyclone III Device Family Configuration Pin Summary  
Bank  
Description  
FLASH_nCE, nCSO  
CRC_ERROR  
Input/Output  
Output  
Output  
Input  
Dedicated  
Powered By  
Configuration Mode  
(2)  
1
6
VCCIO  
AS, AP  
(1)  
VCCIO/Pull-up  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
Pull-up  
Pull-up  
VCCIO  
VCCIO  
VCCIO  
Pull-up  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
VCCINT  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
VCCIO  
Optional, all modes  
PS, FPP, AS  
1
1
8
DATA[0]  
Yes  
(2)  
Bidirectional  
Input  
AP  
FPP  
AS  
DATA[1], ASDO  
DATA[7..2]  
Output  
Bidirectional  
Input  
(2)  
AP  
FPP  
(2)  
Bidirectional  
Bidirectional  
Output  
Bidirectional  
Input  
AP  
(2)  
8
6
1
1
DATA[15..8]  
INIT_DONE  
nSTATUS  
nCE  
AP  
Optional, all modes  
All modes  
Yes  
Yes  
All modes  
Input  
PS, FPP  
1
DCLK  
Yes  
(2)  
Output  
Bidirectional  
Input  
AS, AP  
6
1
1
1
1
6
6
6
1
7
8
6
1
6
6
6
5
5
CONF_DONE  
TDI  
Yes  
Yes  
Yes  
Yes  
Yes  
All modes  
JTAG  
TMS  
Input  
JTAG  
TCK  
Input  
JTAG  
nCONFIG  
CLKUSR  
nCEO  
Input  
All modes  
Optional  
Input  
Output  
Input  
Optional, all modes  
All modes  
JTAG  
MSEL[3..0]  
TDO  
Yes  
Yes  
Output  
Output  
Output  
Output  
Output  
Output  
Output  
Output  
Input  
(2)  
PADD[14..0]  
PADD[19..15]  
PADD[23..20]  
nRESET  
nAVD  
AP  
(2)  
AP  
(2)  
AP  
(2)  
AP  
(2)  
AP  
(2)  
nOE  
AP  
(2)  
nWE  
AP  
(2)  
DEV_OE  
DEV_CLRn  
Optional, AP  
(2)  
Input  
Optional, AP  
Notes to Table 9–21:  
(1) In Cyclone III devices, the CRC_ERRORpin is a dedicated output by default. Optionally, you can enable the CRC_ERRORpin as an open-drain output  
in the CRC Error Detection tab from the Device and Pin Options dialog box.  
(2) AP configuration is for Cyclone III devices only.  
August 2012 Altera Corporation  
Cyclone III Device Handbook  
Volume 1