欢迎访问ic37.com |
会员登录 免费注册
发布采购

5AGTMD3G627C4N 参数 Datasheet PDF下载

5AGTMD3G627C4N图片预览
型号: 5AGTMD3G627C4N
PDF下载: 下载PDF文件 查看货源
内容描述: 阿里亚V器件手册 [Arria V Device Handbook]
分类和应用:
文件页数/大小: 82 页 / 1787 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号5AGTMD3G627C4N的Datasheet PDF文件第70页浏览型号5AGTMD3G627C4N的Datasheet PDF文件第71页浏览型号5AGTMD3G627C4N的Datasheet PDF文件第72页浏览型号5AGTMD3G627C4N的Datasheet PDF文件第73页浏览型号5AGTMD3G627C4N的Datasheet PDF文件第75页浏览型号5AGTMD3G627C4N的Datasheet PDF文件第76页浏览型号5AGTMD3G627C4N的Datasheet PDF文件第77页浏览型号5AGTMD3G627C4N的Datasheet PDF文件第78页  
2–46  
Chapter 2: Device Datasheet for Arria V Devices  
Configuration Specification  
Remote System Upgrades Circuitry Timing Specification  
Table 2–44 lists the timing parameter specifications for the remote system upgrade  
circuitry.  
Table 2–44. Remote System Upgrade Circuitry Timing Specification  
Parameter  
Minimum  
Maximum  
Unit  
(1)  
(3)  
40  
MHz  
tMAX_RU_CLK  
(2)  
tRU_nCONFIG  
250  
250  
ns  
ns  
tRU_nRSTIMER  
Notes to Table 2–44:  
(1) This clock is user-supplied to the remote system upgrade circuitry. If you are using the ALTREMOTE_UPDATE  
megafunction, the clock user-supplied to the ALTREMOTE_UPDATE megafunction must meet this specification.  
(2) This is equivalent to strobing the reconfiguration input of the ALTREMOTE_UPDATE megafunction high for the  
minimum timing specification. For more information, refer to the “Remote System Upgrade State Machine”  
section in the Device Interfaces and Integration Basics for Arria V Devices chapter.  
(3) This is equivalent to strobing the reset timer input of the ALTREMOTE_UPDATE megafunction high for the  
minimum timing specification. For more information, refer to the “User Watchdog Timer” section in the Device  
Interfaces and Integration Basics for Arria V Devices chapter.  
User Watchdog Internal Oscillator Frequency Specification  
Table 2–45 lists the frequency specifications for the user watchdog internal oscillator.  
Table 2–45. User Watchdog Internal Oscillator Frequency Specifications—Preliminary  
Minimum  
Typical  
Maximum  
Unit  
5.3  
7.9  
12.5  
MHz  
Arria V Device Handbook  
February 2012 Altera Corporation  
Volume 1: Device Overview and Datasheet