2–46
Chapter 2: Device Datasheet for Arria V Devices
Configuration Specification
Remote System Upgrades Circuitry Timing Specification
Table 2–44 lists the timing parameter specifications for the remote system upgrade
circuitry.
Table 2–44. Remote System Upgrade Circuitry Timing Specification
Parameter
Minimum
Maximum
Unit
(1)
(3)
—
40
MHz
tMAX_RU_CLK
(2)
tRU_nCONFIG
250
250
—
—
ns
ns
tRU_nRSTIMER
Notes to Table 2–44:
(1) This clock is user-supplied to the remote system upgrade circuitry. If you are using the ALTREMOTE_UPDATE
megafunction, the clock user-supplied to the ALTREMOTE_UPDATE megafunction must meet this specification.
(2) This is equivalent to strobing the reconfiguration input of the ALTREMOTE_UPDATE megafunction high for the
minimum timing specification. For more information, refer to the “Remote System Upgrade State Machine”
section in the Device Interfaces and Integration Basics for Arria V Devices chapter.
(3) This is equivalent to strobing the reset timer input of the ALTREMOTE_UPDATE megafunction high for the
minimum timing specification. For more information, refer to the “User Watchdog Timer” section in the Device
Interfaces and Integration Basics for Arria V Devices chapter.
User Watchdog Internal Oscillator Frequency Specification
Table 2–45 lists the frequency specifications for the user watchdog internal oscillator.
Table 2–45. User Watchdog Internal Oscillator Frequency Specifications—Preliminary
Minimum
Typical
Maximum
Unit
5.3
7.9
12.5
MHz
Arria V Device Handbook
February 2012 Altera Corporation
Volume 1: Device Overview and Datasheet