Safety Isolation System
ElectroGuard
Combination Systems with Fusible Disconnect Switch
Product Selection for Outside North America (see page 12-19 for Ordering Instructions)
3-Phase Max. kW Rating
(50Hz)
Catalogue Num ber ➊
IP 54 Motor Control
Am pere
Rating
Fuse Clip
Rating/
Centre Type
Enclosure (with
bussing)
(AC-3) 230V 400V 500V 600V Typ e ➊
IP 30 Enclosure
IP 54 Enclosure
IP 65 Enclosure
2032*-C0630W -30D
2032*-C0630W -31B
2032*-C0630W -31D
2032*-C0860W -31B
2032*-C0630P -30D 2032*-C0630H -30D
2032*-C0630P -31B 2032*-C0630H -31B
2032*-C0630P -31D 2032*-C0630H -31D
2032*-C0860P -31B 2032*-C0860H -31B
2032-!0630H 30D
2032-!0630H -31B
2032-!0630H -31D
2032-!0860H -31B
630A DIN
630
200
355
450
500 800A BS 88
1600A DIN
800A BS 88
1250A
600
860
250
391
500
710
560
2032*-C0860P -32B 2032*-C0860H -32B
2032*-C0860P -31D 2032*-C0860H -31D
2032*-C1200P -32B 2032*-C1200H -32B
2032-!0860H -32B
2032-!0860H -31D
2032-!1200H -32B
2032-!1200H -31D
2032*-C0860W -32B
2032*-C0860W -31D
2032*-C1200W -32B
2032*-C1200W -31D
BS 88
1600A DIN
1250A
BS 88
1200
888 1043
1600A DIN 2032*-C1200P -31D 2032*-C1200H -31D
To order the Tim e Delay feature, add the following Cat. String to the end of the Catalogue Num ber shown in the table:
Factory set 30 second time delay feature:
-1TD
Example: Catalogue Number 2032-C0180P -29B becomes Catalogue Number 2032-C0180P -29B-1TD to include the time delay feature.
* Input Power Feed Catalogue Num ber Code
The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.
Example: Catalogue Number 2032*-C0630P -31B becomes Catalogue Number 2032T-C0630P -31B for a “Top Feed” input power requirement.
Input Power Feed
Catalogue Num ber Code
Top Feed
T
B
Bottom Feed
! Bussing Designation
The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.
Example: Catalogue Number 2032-!0085H -27D becomes Catalogue Number 2032-E0085H -27D for “600A Line Side Incoming Bus and Outgoing Power
Cables” bussing designation.
Ty p e o f B u s s i n g ➊
Catalogue Num ber Code
600A Line Side Incoming Bus and Outgoing Power Cables
1200A Line Side Incoming Bus and Outgoing Power Cables
Line Side Incoming Power Cables and 600A Load Side Outgoing Bus
Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus
E
D
H
R
Input Line Voltage Code
The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.
Example: Catalogue Number 2032-C0085W -26B becomes Catalogue Number 2032-C0085WN-26B for a 380V 50Hz Input Line Voltage application.
Input Line Voltage
220V 50Hz
A
380-400V 50Hz 400-415V 50Hz 440V 50Hz
500V 50Hz
M
550V 50Hz
C
Voltage Code for Catalogue Number
N
G
B
Product Selection: Remote Lockout Station ➊
Catalogue Num ber
IP 54 Enclosure
2030-RLSHG
“System Isolated” Light Colour
Green
IP 30 Enclosure
2030-RLSPG
IP 65 Enclosure
2030-RLSW G
➊ Power fuses are not included with the disconnect switch. Select power fuses in accordance with applicable local codes.
➊ Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine operator
to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off” position.
Consult your local Rockwell Automation sales office for other time settings.
➊ Bus Type: Copper with tin plating. Consult factory for other types of bussing.
➊ Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).
Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).
12-9