Safety Isolation System
ElectroGuard
Combination Systems with Thermal-magnetic Circuit Breaker
! Bussing Designation
The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.
Example: Cat. No. 2033-!0085J -44 becomes Cat. No. 2033-M0085J -44 for “600A Line Side Incoming Bus and Outgoing Power Cables” bussing designation.
Ty p e o f B u s s i n g ➊
Catalogue Num ber Code
600A Line Side Incoming Bus and Outgoing Power Cables
1200A Line Side Incoming Bus and Outgoing Power Cables
Line Side Incoming Power Cables and 600A Load Side Outgoing Bus
Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus
M
S
F
B
Input Line Voltage Code
The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.
Example: Catalogue Number 2033-A0085J -44 becomes Catalogue Number 2033-A0085JB-44 for a 480V 60Hz Input Line Voltage application.
Input Line Voltage
208V 60Hz
H
240V 60Hz
A
480V 60Hz
B
600V 60Hz
C
Voltage Code for Catalogue Number
Product Selection: Remote Lockout Station ➊
Catalogue Num ber
“System Isolated” Light Type 1 General Purpose
Type 12 Dust tight
Type 4 W atertight
Type 4X W atertight
Colour
Enclosure
Enclosure
Painted Steel Enclosure Stainless Steel Enclosure
White
2030-RLSAW
2030-RLSJW
2030-RLSFW
2030-RLSCW
Combination Systems with Thermal-magnetic Circuit Breaker
Product Selection for Outside of North America (see page 12-19 for Ordering Instructions)
3-Phase Max. kW Rating
(50Hz)
Catalogue Num ber ➊
IP 54 Motor Control
Am pere
Rating
(AC-3)
Centre Type Enclosure
(w/bussing)
230V 400V 500V 600V
IP 30 Enclosure
IP 54 Enclosure
IP 65 Enclosure
4
5.5
7.5
-
4
5.5
7.5
11
-
4
5.5
7.5
11
-
4
5.5
7.5
11
-
2033-C0023P -39K 2033-C0023H -39K
2033-C0023P -40K 2033-C0023H -40K
2033-C0023P -41K 2033-C0023H -41K
2033-C0023P -42K 2033-C0023H -42K
2033-C0043P -42K 2033-C0043H -42K
2033-C0043P -43K 2033-C0043H -43K
2033-C0043P -44K 2033-C0043H -44K
2033-C0043P -45K 2033-C0043H -45K
2033-C0043P -46K 2033-C0043H -46K
2033-C0085P -44K 2033-C0085H -44K
2033-C0085P -45K 2033-C0085H -45K
2033-C0085P -46K 2033-C0085H -46K
2033-C0085P -47K 2033-C0085H -47K
2033-C0085P -48K 2033-C0085H -48K
2033-C0085P -49K 2033-C0085H -49K
2033-C0085P -50K 2033-C0085H -50K
2033-C0110P -48K 2033-C0110H -48K
2033-C0110P -51K 2033-C0110H -51K
2033-C0110P -52K 2033-C0110H -52K
2033-!0023H -39K
2033-!0023H -40K
2033-!0023H -41K
2033-!0023H -42K
2033-!0043H -42K
2033-!0043H -43K
2033-!0043H -44K
2033-!0043H -45K
2033-!0043H -46K
2033-!0085H -44K
2033-!0085H -45K
2033-!0085H -46K
2033-!0085H -47K
2033-!0085H -48K
2033-!0085H -49K
2033-!0085H -50K
2033-!0110H -48K
2033-!0110H -51K
2033-!0110H -52K
2033-C0023W -39K
2033-C0023W -40K
2033-C0023W -41K
2033-C0023W -42K
2033-C0043W -42K
2033-C0043W -43K
2033-C0043W -44K
2033-C0043W -45K
2033-C0043W -46K
2033-C0085W -44K
2033-C0085W -45K
2033-C0085W -46K
2033-C0085W -47K
2033-C0085W -48K
2033-C0085W -49K
2033-C0085W -50K
2033-C0110W -48K
2033-C0110W -51K
2033-C0110W -52K
23
43
11
13
-
13
15
18.5
22
-
13
15
18.5
22
-
13
15
18.5
22
-
-
-
15
18.5
22
25
-
-
-
-
-
-
-
85
25
32
37
45
-
25
32
37
45
-
25
32
37
45
-
-
-
32
-
110
55
-
55
63
55
63
-
➊ Bus Type: Copper with tin plating. Consult factory for other types of bussing.
➊ Safety Isolation Systems rated up through 85A can support a maximum of four (4) Remote Lockout Stations (RLS).
Systems rated from 110A - 1200A can support a maximum of six (6) RLS. If additional RLS are required, order the optional Expansion Module(s) (see page 12-16).
➊ Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine
operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off”
position. See page 12-14 for instructions on how to order the optional time delay feature. Consult your local Rockwell Automation sales office for other time settings.
12-12