 浏览型号2032-A0420FX-30L的Datasheet PDF文件第1页浏览型号2032-A0420FX-30L的Datasheet PDF文件第2页浏览型号2032-A0420FX-30L的Datasheet PDF文件第3页浏览型号2032-A0420FX-30L的Datasheet PDF文件第4页浏览型号2032-A0420FX-30L的Datasheet PDF文件第5页浏览型号2032-A0420FX-30L的Datasheet PDF文件第7页浏览型号2032-A0420FX-30L的Datasheet PDF文件第8页浏览型号2032-A0420FX-30L的Datasheet PDF文件第9页  
Safety Isolation System
ElectroGuard
Optional Features (continued)
Expansion Module (Can be ordered separately):
For applications requiring more
than the maximum allowable
Remote Lockout Stations, or
total wire lengths longer than
those permitted with the
Remote Lockout Stations.
Expansion Modules are
available in 4 or 10 port
configurations. Each Expansion
Module is wired to a port on the Control Module, and takes the
connection port that would normally accommodate a Remote
Lockout Station (see page 12-18 to determine if an Expansion
Module is required due to wire length considerations).
The 23A through 85A systems will accommodate connection of a
maximum of 4 Expansion Modules, and the 110A through 1200A
systems will accommodate connection of a maximum of 6
Expansion Modules.
Certain ampere size Safety Isolation System Power Panels can
accommodate either 1 or 2 Expansion Modules installed internally.
In all other instances the Expansion Module(s) must be located
external to the Safety Isolation System in a suitably rated enclosure.
Ampere Size of Safety
Isolation System
23A - 85A
110A - 420A
Internal Provisions to Accommodate
Expansion Modules
None
Provisions to accept one (1) Expansion
Module (Bulletins 2031, 2032 or 2033)
Provisions to accept up to two (2)
Expansion Modules in Bulletin 2032 or 2033
combination systems, or one (1) Expansion
Module in Bulletin 2031 non combination
systems.
4 port
4 port w/ time delay
10 port
10 port w/time delay
Note:
The time delay feature affects all input devices wired to the
Expansion Module.
For Expansion Module(s) Factory Installed:
Add One of the Following Catalogue Number Strings to
the Safety Isolation System Catalogue Number:
Number of
Expansion Modules
One (available on
Bulletin 2031, 2032,
or 2033, 110A–
1200A Systems only)
Two (available on
630A – 1200A
Bulletin 2032 or 2033
Systems only)
Number of Ports
per Expansion
Module
4
4 w/time delay
10
10 w/time delay
4
4 w/time delay
10
10 w/time delay
Catalogue Number
String
-1EUF
-1EUFTDA
-1EUT
-1EUTTDA
-2EUF
-2EUFTDA
-2EUT
-2EUTTDA
e.g. Catalogue Number
2032T
-A0630JB-30L
becomes Catalogue Number
2032T
-A0630JB-30L-2EUT
to indicate a 630A Safety Isolation System that
includes 2 internally installed 10 port Expansion Modules without the time delay
feature.
Open Type Expansion Module for Field Addition
Open Type
Description
Catalogue Number
2030-EUNF
2030-EUNF-1TDA
2030-EUNT
2030-EUNT
-1TDA
630A - 1200A
Requires user supplied enclosure if not installed in the Safety Isolation System
Power Panel.
To order the Status Communication to a remote PLC option installed in an
enclosed Expansion Module, add one of the following Catalogue Strings to the
Expansion Module Catalogue Number:
Expansion Modules may be ordered with an adjustable time delay
feature (1-30 seconds) in order to allow time for the machine
operator to shut-down drives or other equipment that requires a
controlled stop after a Remote Lockout Station has been switched to
the “Off ” position. Consult your Rockwell Automation sales office
for other time settings.
Enclosed Expansion Modules are available with optional “Flex”
modules to provide status communication to a remote PLC.
Communication can be via DeviceNet or Remote I/O.
Note:
The status communication option allows a remote PLC to receive
status signals from the Expansion Module. The Expansion Module does
not accept input signals from DeviceNet or Remote I/O.
Communication
Platform
Remote I/O
DeviceNet
Number of I/O
Points
16 points
16 points
Catalogue
Number String
-1COM
-1DNET
e.g. Catalogue Number 2030-EUJF becomes Catalogue Number 2030-EUJF-
1COM to indicate a Type 12 enclosed, 4-port expansion module, with 16 points
of remote I/O.
To order the optional enclosed Expansion Module for field addition for North America:
Catalogue Number
Description
4 port
4 port w/ time delay
10 port
10 port w/time delay
Type 1 Enclosure
2030-EUAF
2030-EUAF-1TDA
2030-EUAT
2030-EUAT
-1TDA
Type12
Enclosure
Type 4 Painted Enclosure
2030-EUFF
2030-EUFF-1TDA
2030-EUFT
2030-EUFT
-1TDA
Type 4X Stainless Steel Enclosure
2030-EUCF
2030-EUCF-1TDA
2030-EUCT
2030-EUCT
-1TDA
2030-EUJF
2030-EUJF-1TDA
2030-EUJT
2030-EUJT
-1TDA
To order the optional enclosed Expansion Module for field addition for outside of North America:
Catalogue Number
Description
4 port
4 port w/ time delay
10 port
10 port w/time delay
IP30 Enclosure
2030-EUPF
2030-EUPF-1TDA
2030-EUPT
2030-EUPT
-1TDA
IP54 Enclosure
2030-EUHF
2030-EUHF-1TDA
2030-EUHT
2030-EUHT
-1TDA
IP65 Enclosure
2030-EUWF
2030-EUWF-1TDA
2030-EUWT
2030-EUWT
-1TDA
12-16