[AK4706]
■ Register Map
Addr
Register Name
D7
D6
D5
D4
D3
D2
D1
D0
00H Control
DEM1
VMUTE
0
DEM0
DIF1
VCR1
L5
DIF0
VCR0
L4
AUTO
MONO
L3
DAPD
VOL
L2
MUTE
TV1
STBY
TV0
01H Switch
0
0
02H Main volume
03H Zerocross
L1
L0
0
VMONO
VRF0
TVFB
VCLP1
SBIO0
0
1
DVOL1
VVCR1
VCRV
CLAMP2
SBV0
DVOL0
VVCR0
TVB
MOD
VTV2
TVG
MDT1
VTV1
TVR
MDT0
VTV0
TVV
04H Video switch
05H Video output enable
06H Video volume/clamp
07H S/F Blanking control
08H S/F Blanking monitor
09H Monitor mask
0AH HD switch
VRF1
CIO
VVCR2
VCRC
VCLP0
SBV1
FVCR1
CLAMPB
SBIO1
0
CLAMP1 CLAMP0
VVOL1
FB1
VVOL0
FB0
SBT1
VCMON
MVC
SBT0
FVCR0
MFVCR
0
TVMON
MTV
SVCR1
MSVCR
HDSW1
FLY1
SVCR0
0
MCOMN
HDCP1
0
0
HDCP0
0
HDAPW
FLPR1
SDC
VCLP2
FLPB1
HDSW0
FLY0
0BH HD filter
FLPR0
FLPB0
When the PDN pin goes “L”, the registers are initialized to their default values.
While the PDN pin =“H”, all registers can be accessed.
Do not write any data to the register over 0BH.
MS0507-E-01
2010/09