9.4. Description of Each Operation Mode  
9.4.1. Power-down Mode  
Power to almost all internal circuits is turned off. All registers are accessible in Power-down mode. Data  
stored in read/write registers are remained. They can be reset by soft reset.  
9.4.2. Single Measurement Mode  
When Single measurement mode (MODE[4:0] bits = 00001) is set, magnetic sensor measurement is  
started. After magnetic sensor measurement and signal processing is finished, measurement magnetic data is  
stored to measurement data registers (HXL to HZH), then AK09916 transits to Power-down mode  
automatically. On transition to Power-down mode, MODE[4:0] bits turns to 00000. At the same time,  
DRDY bit in ST1 register turns to 1. This is called Data Ready. When any of measurement data register  
(HXL to TMPS) or ST2 register is read, DRDY bit turns to 0. It remains 1on transition from  
Power-down mode to another mode. (Figure 9.2. )  
When sensor is measuring (Measurement period), measurement data registers (HXL to TMPS) keep the  
previous data. Therefore, it is possible to read out data even in measurement period. Data read out in  
measurement period are previous data.(Figure 9.3. )  
Operation Mode:  
Power-down  
Single measuremnet  
(1)  
(2)  
(3)  
Measurement period  
Measurement Data Register  
Last Data  
Measurement Data (1)  
Data(2)  
Data(3)  
DRDY  
Data read  
Data(1)  
Data(3)  
Register Write  
MODE[4:0]="00001"  
MODE[4:0]="00001" MODE[4:0]="00001"  
Figure 9.2. Single measurement mode when data is read out of measurement period  
Operation Mode:  
Power-down  
Single measuremnet  
(1)  
(2)  
(3)  
Measurement period  
Measurement Data Register  
Last Data  
Measurement Data (1)  
Data(3)  
DRDY  
Data read  
Data(1)  
Register Write  
MODE[4:0]="00001"  
MODE[4:0]="00001" MODE[4:0]="00001"  
Figure 9.3. Single measurement mode when data read started during measurement period  
015007392-E-02  
2015/12  