AIC809/AIC810
ꢀELECTRICAL CHARACTERISTICS
(Typical values are at TA=25°C, unless otherwise specified.) (Note 1)
PARAMETER
Operating Voltage Range
Supply Current
TEST CONDITIONS
MIN.
TYP. MAX. UNIT
SYMBOL
VCC
0.9
6
V
ICC
VCC = VTH +0.1V
1
3
µA
TA=+25°C
2.265
2.3
2.335
2.346
2.639
2.652
2.944
2.958
3.147
3.162
4.060
4.080
4.466
4.488
4.669
4.692
AIC809-23
AIC809-26
AIC809-29
TA= -40°C to +85°C 2.254
TA=+25°C 2.561
TA= -40°C to +85°C 2.548
TA=+25°C 2.857
TA= -40°C to +85°C 2.842
TA=+25°C 3.054
TA= -40°C to +85°C 3.038
TA=+25°C 3.940
TA= -40°C to +85°C 3.920
TA=+25°C 4.334
TA= -40°C to +85°C 4.312
2.6
2.9
3.1
4.0
4.4
4.6
Reset Threshold
VTH AIC809-31
AIC809-40
V
AIC809-44
TA=+25°C
4.531
4.508
AIC809-46
TA=-40°C to +85°C
VCC to Reset Delay
TRD VCC=VTH to (VTH -0.1V), VTH=3.1V
20
µS
TA=+25°C
140
100
230
560
Reset Active Timeout Period TRP VCC = VTH (MAX)
mS
TA= -40°C to +85°C
1030
VOH VCC=VTH+0.1V, ISOURCE=1mA
VOL VCC=VTH - 0.1V, ISINK=1mA
0.8VCC
RESET
Output Voltage
V
V
0.2Vcc
VOH
VOL
0.8VCC
V
CC=VTH-0.1V, ISOURCE=1mA
CC=VTH+0.1V, ISINK=1mA
RESET Output Voltage
0.2Vcc
V
Note1: Specifications are production tested at TA=25°C. Specifications over the -40°C to 85°C operating
temperature range are assured by design, characterization and correlation with Statistical Quality
Controls (SQC).
RESET
Note2:
output is for AIC809; RESET output is for AIC810.
4